INSTALLATION PRECAUTIONS

CAUTION This equipment is not ignition protected and employs components that can produce arcs or sparks. To reduce the risk of fire or explosions, do not install in unvented compartments containing batteries or flammable gasses or areas in which ignition-protected equipment is required.

WARNING

For continued protection against risk of electric shock, use only the ground-fault circuit interrupter (GFCI) type receptacles detailed in this manual. Other types may fail to operate properly when connected to this inverter, resulting in a potential shock hazard.

CAUTION To reduce the risk of electric shock and prevent premature failure due to corrosion, do not mount where exposed to rain, dripping or spray.

CAUTION To reduce the risk of fire, do not obstruct ventilation openings. Do not mount in a zero clearance compartment— overheating may result.

CAUTION Risk of electrical shock. Both AC & DC voltage sources are terminated inside this equipment. Before servicing, disconnect all inputs and outputs.

Confirm that your shipping carton contains:

Inverter/Charger

TSC temperature sensor with 15' cable

Owner’s manual

Warranty card

Jumper for AUX Switch (only used without Remote Control Panel)

Wire nuts

Typical Tools Needed

Flathead and Phillips screwdrivers Allen (Hex) screwdriver (1/8'')

Wrench for connecting battery cables (9/16'') Wire cutters

Wire strippers

Misc. assortment of wire ties and connectors

Accessories Needed for Installation Fuse - UL Listed DC Rated slow blow fuse as required by NEC.

Electrical wire (10 gauge) for AC input wiring. Consult NEC for proper size for output wiring.

Battery cables 1-Positive, 1-Negative Consult NEC for proper size

DC fuse cable Mounting screws (4)

21