OPERATION

STATUS LEDs

Each Status LED performs two functions, providing battery type selection and operation status.

Status LEDs

INVERT CHARGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMOTE TSC

 

 

OVERTEMP

 

 

OVERLOAD / AGM

 

 

LOW BATTERY / GEL 2

 

 

 

 

 

 

 

CHARGE / GEL1

INVERT/WET

Battery Type Selection

After holding the INVERT button down for five seconds, use the CHARGE button to select battery type :

WET GEL 1 GEL 2 AGM

Operation Status

INVERT - Green LED

The INVERT push-button switch is located on the front of the unit.

When the LED is solid green, the unit is in invert mode. This occurs by pressing the INVERT switch (for three to five seconds).

When the LED is blinking slowly (once per second), the inverter is in standby with AC power applied and the transfer switch engaged

Press the INVERT switch again to turn the inverter OFF.

CHARGE - Green LED

The CHARGE push-button switch is located on the front of the unit.

When external AC is applied to the AC input of the unit, the charger automatically turns ON. The CHARGE LED will be solid green.

When the LED is blinking slowly, (once per second) the charger is ready, but external AC power is not available.

Press the CHARGE switch again to turn the charger OFF. The charger defaults to ON when operating without a remote or with the Remote Control Panel.

When the LED is OFF, the charger has been manually turned OFF. This can only be accomplished while AC power is being supplied.

NOTE: When AC power is available, the default setting for the charger is ON. If the unit was manually turned OFF and AC power is interrupted and becomes available again, the charger will return to ON.

LOW BATTERY - Red LED

When the LED is OFF the battery voltage is normal, between 10.5 and 15.0 volts DC.

When the LED is solid red, it indicates a battery warning condition, the battery voltage is below 10.5 volts DC or above 15.0 volts DC.

When the LED is blinking slowly (once per second), a battery shutdown has occurred. The voltage is either below 10.0 volts DC or above 15.5 volts DC.

When the LED is blinking rapidly (five times per second), a potential problem in the DC system has been detected. Check your batteries, battery cables and DC loads.

OVERTEMP/OVERLOAD - Red LED

When the LED is OFF, operation is normal.

When the LED is red, there is an over temp or overload condition. Check for excessive loads or short circuit on the output of the inverter. Correct the condition and restart by pushing the INVERT switch.

8