SPECIFICATIONS
Nominal Battery Charge
Battery Voltage Range
Low Battery Cutout
AC Input Voltage Range
Frequency Regulation
Inverter Output Power (Continuous)
Inverter Voltage Regulation
Wave Shape
Surge Power
No Load Current Drain (Idle Mode) Power Factors Allowed
Full Load Efficiency
Peak Efficiency
Protection
Charging Rate
AC Input (Max. Charge Mode) Bulk Charge Voltage
Float Charge Voltage
Equalizing Charge Voltage
Status Panel
Weight
Dimensions
12 VDC
10.0to 15.5 VDC
10.0VDC (+/- 0.5)
Minimum 90 VAC/Normal 130 VAC 50 or 60 Hz Quartz Regulated 3000 VA
120 V +/- 5% true RMS Modified Sine Wave 75 amps
.12 amps All
86% (60 Hz)
93%
Over/under utility voltage, over/under battery voltage, short circuit, circuit breaker, over temperature, backfeed
140 amps (three stage)
28amps 14.3 VDC* 13.4 VDC* 16.3 VDC* Optional remote
50lbs.
13.2'' L x 11.5'' W x 7.9'' H
*variable on unit with Temperature Sensor installed and adjustable by Battery Type selected on the inverter/charger control panel or from the Remote Control Panel.
35