F08 - SET PEUKERT'S EXPONENT
DEFAULT = 1.25 | RANGE = | STEP = 0.01 |
Sets the exponent for Peukert’s equation. A setting of 1.00 defeats Peukert's calculation. See pages
F09 - Ah OR RATE COMPENSATED % REMAINING MODE
DEFAULT OFF = Ah DISPLAY MODE
ON = RATE COMPENSATED PERCENT REMAINING MODE
Changes the A hrs function to % Remaining mode, which displays the selected battery's rate compensated
This option is not available when F04 or F05 is ON.
F10 - ALTERNATOR CURRENT LIMIT |
| |
DEFAULT = 100 | RANGE = | STEP=10AMPS |
This function is only used with the Alternator Regulator Model (Link
F11 - BATTERY #2 USED FOR CONTROL
DEFAULT ON = BATTERY #2 USED FOR CONTROL
OFF = BATTERY #2 IS NOT USED FOR CONTROL
This function is used to defeat Battery #2 as a part of the charger control function of the FREEDOM inverter (also alternator control in the Link
NOTE: This function is not changed in a reset to factory default values. If you wish to change this function you must use the setup routine to change it.
F12 - BACKLIGHTING INTENSITY CONTROL |
| |
DEFAULT = 130 | RANGE = | STEP = 10 |
This function may be used to increase or decrease the intensity of the backlighting for the display.
13