F13 SET DISCHARGE FLOOR |
|
DEFAULT = 100% RANGE = | STEP = 5% |
When this option is activated, you may set a discharge floor for each battery bank. When the discharge floor is set to 50%, the Time Remaining display reports time remaining until the battery reaches the 50% discharged level. You may set the discharge floor from 50% to 100% in 5% increments. When the Settable Discharge Floor is 100%, time remaining to 100% discharge is displayed. You may set a discharge floor for each battery. The settable floor is applied to the battery selected (BAT1 or BAT2) at the time you enter this function. You may wish to set a higher discharge floor, such as 50%, for an engine starting bank and a deeper floor, such as 75%, for a
F14 - ACTIVE TEMPERATURE COMPENSATION ON, OFF
DEFAULT = OFF RANGE = OFF, ON
When this function is ON, the Link 2000/Link
F15 - SPECIAL FUNCTION FOR DIAGNOSTIC USE.
DEFAULT ON = INVERTER CONTROL
OFF = ASCII OUTPUT
CAUTION!! LEAVE THIS FUNCTION ON. TURNING IT OFF DISABLES COMMUNICATION. TO BE USED FOR SERVICE DIAGNOSTIC PURPOSES ONLY.
SUMMARY OF SOFTWARE DEFAULTS |
| ||||
| Function | Name | Default | Options | |
| F01 | Averaging Period | 0 | 4, 16, 32 minutes | |
** | F02 | Battery Type | Lead Acid | Gel cell , AGM | |
** | F03 | View or set ambient | 70 °F | See text | |
|
| temperature |
|
| |
| F04 | View Ah or kWh | OFF (Ah) | ON (kWh) | |
| F05 | Alternative Energy mode | Off | Solar cell (see text) | |
| F06 | Peukert's Exponent | Auto | See text | |
| F07 | Temp Coefficient | 0.5 | 0.1 to 0.9 | |
** | F08 | Puekert's Exponent | 1.25 | 1.00 to 1.50 (see text) | |
| F09 | % remaining time display | Off (Ah mode) | On (% remaining) | |
| F10 | Alternator Current limit | 100 amps | 30 to 220 amps, off | |
| F11 Battery #2 used for control | On (Yes) | Off | ||
| F12 | Backlighting intensity | 130 | 0 to 240 | |
| F13 | Settable discharge floor | 100% | 50% to 100% | |
| F14 | Active Temp Compensation | Off | On | |
| F15 | Manufacturer Reserved | On | Do not change |
** Item that should be confirmed or changed at installation to ensure proper operation