SETUP

 

 

Link 2000

 

 

 

 

 

 

 

 

 

 

 

 

C o n t r o l

 

 

 

B a t t e r y

I n v e r t

I 4 . 3 5

1

 

Idle Mode

Reset A hrs

 

 

 

Charger

 

 

 

2

 

Pwr Share

 

 

 

Data

S e t u p

V o l t s

A m p s

A h r s

T i m e

Charged V

Charged %

B att Ca p

F u n c t i o n

 

 

 

E q u a l i ze

 

 

 

St a t us : A C I n

Charge

Accept

F l o a t

The LINK 2000 has been set up with default values chosen to work with a typical system. Normally the only values that must be changed are:

1)

Battery capacity (page 9)

3) Battery type (liquid or gel) (F02 page 11).

2)

Ambient Temperature (F03 page 11)

4) Peukert's exponent (F08 page 13).

The SETUP BUTTON is used to access the functions in small blue text below each button's primary function. It is also used for certain advanced functions described later. To set up a value or function:

1)Select the battery to be set up by pressing Battery #1 or #2, (or Invert, or Charge, when setting up Idle Mode or Pwr Share).

2)Hold down the SETUP BUTTON until the green LED flashes at one-second intervals.

3)Release the SETUP BUTTON and press and hold the function to be set up. The LED of the function being set up will also begin to flash at one-second intervals. The present value of the function will appear in the display.

4)After three seconds, with the button pressed, the display will begin scrolling. When the desired value appears, release the button. If you continue to hold down the button, the display will increment to the end of its range, roll over to its minimum value, and continue to scroll. You may also "bump" a value by repeatedly pressing the button.

You may set up additional values, or functions, as long as the SETUP LED continues to flash. When the SETUP LED stops flashing, all values that were changed during the setup routine will be stored in nonvolatile memory.

SUMMARY OF FACTORY DEFAULT VALUES

INVERTER/CHARGER CONTROL

Standby

= 4 watts (5 watts in Series 458 units)

Power Sharing

= 30 amps ("OFF" for Freedom 25)

MONITORING FUNCTIONS

Charged Voltage

= 13.2 volts for 12 volt systems

=26.4 volts for 24 volt systems

Charged Current % = 2% (of battery capacity)

Battery Capacity = 200 Ah

CEF (Charge Efficiency Factor)= 87% for Liquid Acid

= 90% for other cell types

Ambient Temp. = 70 °F

Type= #0 Liquid Peukert's Exponent= 1.25

7