SETUP AND HISTORICAL DATA SUMMARY
The following table is a summary of the values that may be changed through setup or by accumulating historical data. The column on the right is provided to write down your setup values or historical data. Be sure and know these values before calling for customer service. Multiply voltage values by two for
PARAMETER | DEFAULT VALUE | SETUP VALUE |
B1 VCHARGED | 13.2 (13.5 IF F05 IS ON) | ______________ |
B2 VCHARGED | 13.2 (13.5 IF F05 IS ON) | ______________ |
B1 AMPSCHARGED | 2% (4% IF F05 IS ON) | ______________ |
B2 AMPSCHARGED | 2% (4% IF F05 IS ON) | ______________ |
B1 BAT CAPACITY | 200 Ah (800 IF F05 IS ON) | ______________ |
B2 BAT CAPACITY | 200 Ah (800 IF F05 IS ON) | ______________ |
AMBIENT TEMP (F03) | 70 °F | ______________ |
BATTERY TYPE (F02) | #0 LIQUID LEAD ACID | ______________ |
POWER SHARE | 30 A (OFF in Freedom 25) | ______________ |
STANDBY | 4 W | ______________ |
B1 USER CEF (F06) | 87% (90% FOR GELLED) | ______________ |
B2 USER CEF (F06) | 87% (90% FOR GELLED) | ______________ |
TIME REMAINING (F01) | 0 = INSTANTANEOUS | ______________ |
Ah OR kWh(F04) | OFF = Ah | ______________ |
ALT. ENERGY MODE (F05) | OFF | ______________ |
TEMP. COEFFICIENT (F07) | 0.5 | ______________ |
PEUKERT'S EXP. (F08) | 1.25 | ______________ |
BATT #2 FOR CNTRL (F11) | ON = YES | ______________ |
BACKLIGHTING (F12) | 130 | ______________ |
DISCHARGE FLOOR (F13) | 100% | ______________ |
TEMP. COMP. (F14) | OFF | ______________ |
HISTORICAL DATA | VALUE |
B1 # of CEF RECALCS | ______________ |
B2 # OF CEF RECALCS | ______________ |
B1 AVG DEPTH OF DISCHARGE | ______________ |
B2 AVG DEPTH OF DISCHARGE | ______________ |
B1 DEEPEST DISCHARGE | ______________ |
B2 DEEPEST DISCHARGE | ______________ |
SOFTWARE REVISION | ______________ |
32