Feature Summary of LINK 2000

Control Functions

Green LED indicates on.

INVERTER may be turned On or Off independently from charger.

IDLE MODE sets the load sensitivity while idling, expressed in Watts. Range depends on Freedom inventer being used.

CHARGER feature may be turned On or Off independently from inverter.

PWR SHARE sets the AC current limit at which the battery charge rate is reduced to avoid overloading limited AC sources. Expressed in Amps.

Range = 5A, 15A, 20A, 30A, (Varies by Freedom model)

SET UP allows the selection of various functions

Integrated Battery Monitoring & Inverter/Charger ControlBattery Display Select

Green LED indicates selection.

Press to select BATTERY #1.

RESET A hrs of the selected battery to zero.

Press to select BATTERY #2.

DATA Displays historical data about battery.

Monitoring Functions

Green LED indicates parameter displayed.

TIME REMAINING of operation of load with remaining battery capacity, displayed as hours.

FUNC Allows special set ups to tailor meter to your particular application.

and values.

Press for 5 seconds to enter Set Up mode. The green LED will flash at 1 second intervals. Then press the function to be set up. The present value will be displayed. After 3 seconds, with the button pressed, the display will begin scrolling. When the desired value appears, release the button. If the button continues to be held down, the display will increment to the end of its range where it will roll over to its minimum value and contine to scroll.

Flashing green LED indicates Set Up mode. The LED of the function being set up also flashes.

STATUS indicators show the presence of AC power and the charge cycle state.

START EQUALIZE function of charger by pressing SET UP button for 5 seconds followed by simultaneously pressing the VOLTS and A hrs buttons until the "E" in the display goes out (3 sec.).

Red CHARGE LED flashes when in equalize mode.

AMP-HOURSconsumed from selected battery displayed as a negative number. Overcharge A hrs displayed as positive number. BATT CAP sets battery

capacity. Default value=200Ahrs. Range 20–2000 Ahrs in 20 Ahr increments.

AMPS charging into the selected battery are displayed as a positive number. Discharge Amps displayed as a negative number. Range + 500 Amps with 0.1A resolution below 42A and 1A resolution above 42A.

CHARGED % sets the current that the charge rate must fall below for the battery to be considered full. Default value=2% of battery capacity. (Ex: 4Amps = 200 x 2%). Range 1–7% in 1% increments. .

VOLTAGE of selected battery is displayed. Range 8.5– 50 Volts with 0.05V resolution.

CHARGED V sets the Voltage the battery must be above to be considered full. Default value = 13.2V or 26.4V Sets default automatically for 12V or 24V systems..

AC IN: Green LED on when AC is present.

CHARGE: Red LED on when charger is in Bulk Charge mode. Flashes Red when charger is in Equalize mode.

ACCEPT: Orange LED on when charger is in Acceptance mode.

FLOAT: Green LED on when charger is in Float mode.

Range 13–32V in 0.1V increments.