Setting Changes

Automatic Generator Equalize Charging

If the inverters are set to automatically charge the batteries using the generator, the equalize process will begin during the next, automatically started, generator run period. When the equalizing process has completed, the generator automatically stops and the cursor returns to the OFF position in the 01B EQ CHARGE menu item on the generator-controlling inverter. The non-generator-controlling inverter must be set from EQ to OFF from the 01B EQ CHARGE menu item or it will start another equalize charge the next time the generator is started.

Manual Equalize Charging

If the batteries were equalized using a manually started generator or from the utility grid, the FLOAT LED illuminates, indicating the equalization process is complete. Set the cursor to OFF on both inverters under the 01B EQ CHARGE menu item when the equalization process is complete.

Important: If using multiple battery temperature sensors (BTS) ensure they are all connected to the same location (battery).