Operation
28 975-0210-01-01
Batt. Full LED
The yellow Batt. Full LED indicates the state of charge on the
batteries. This LED will not illuminate until the batteries have
charged up to at least 90% (according to the inverter/charger’s
estimate). The duration of the LED’s on time will increase
until the batteries reach 100%, at which time the LED will be
on solid. In the inverter mode, the off time duration of the LED
will increase until the batteries discharge to below 90%, at
which time the LED will turn off.
Error LED
The Error LED indicates that there is a problem with the
inverter/charger, batteries or generator. Check the LCD
screen to find and correct the nature of the problem. For more
information, see “Genset Error Messages (RC/GS Only)” on
page 32 and “Inverter/Charger Error Messages” on page 37.
LCD ScreenThe screen is used for setting up the system operation as well
as viewing current status or error messages. It has two 16-
character lines and a backlight. You can scroll through the
screen items by using the buttons below the screen.
Batt. Full LED Other LEDs or
Devices Meaning
Solid Battery fully charged (100%)
Flashing Yellow charge
LED (flashing) Battery charged 90% or higher
OFF Battery below 90% charge
Error Other LEDs or Devices Meaning
ON (Solid) Check system
Figure 4-2
LCD screen
System Status:
Equalizing