Operation
28 975-0210-01-01

Batt. Full LED

The yellow Batt. Full LED indicates the state of charge on the
batteries. This LED will not illuminate until the batteries have
charged up to at least 90% (according to the inverter/charger’s
estimate). The duration of the LED’s on time will increase
until the batteries reach 100%, at which time the LED will be
on solid. In the inverter mode, the off time duration of the LED
will increase until the batteries discharge to below 90%, at
which time the LED will turn off.

Error LED

The Error LED indicates that there is a problem with the
inverter/charger, batteries or generator. Check the LCD
screen to find and correct the nature of the problem. For more
information, see “Genset Error Messages (RC/GS Only)” on
page 32 and “Inverter/Charger Error Messages” on page 37.
LCD Screen
The screen is used for setting up the system operation as well
as viewing current status or error messages. It has two 16-
character lines and a backlight. You can scroll through the
screen items by using the buttons below the screen.
Batt. Full LED Other LEDs or
Devices Meaning
Solid Battery fully charged (100%)
Flashing Yellow charge
LED (flashing) Battery charged 90% or higher
OFF Battery below 90% charge
Error Other LEDs or Devices Meaning
ON (Solid) Check system
Figure 4-2
LCD screen

System Status:

Equalizing

RC-GS_manual.book Page 28 Thursday, May 26, 2005 4:58 PM