Xantrex Technology Solar 400 manual DC Power Section, Internal Battery Section, USB Section

Models: Solar 400

1 66
Download 66 pages 48.53 Kb
Page 58
Image 58
DC Power Section

Specifications

 

Normal operating temperature

77 ºF

 

 

 

(25 ºC)

 

 

 

 

 

 

Operating temperature range

32 – 104 ºF

 

 

 

(0 – 40 ºC)

 

 

 

 

 

 

Storage temperature range

-4 – 140 ºF

 

 

 

(-20 – 60 ºC)

 

 

 

 

 

 

 

 

 

 

DC Power Section

 

 

 

 

 

 

 

DC output power (maximum continuous load)

12 A with overload

 

 

 

protection and automatic

 

 

 

reset

 

 

 

 

 

 

DC charger input socket polarity

Female, center positive

 

 

 

 

 

 

Built-in ambient LED light

12 hi-bright white LEDs

 

 

 

with diffuser

 

 

 

 

 

 

 

 

 

 

Internal Battery Section

 

 

 

 

 

 

 

Internal battery type

sealed, AGM (Absorbed

 

 

 

Glass Mat) lead acid

 

 

 

 

 

 

Internal battery voltage (nominal)

12 Vdc

 

 

 

 

 

 

Internal battery capacity (minimum)

10 Ah

 

 

 

 

 

 

Maximum charge current

0.75 Adc

 

 

 

 

 

 

Peak charging voltage (nominal)

14.8 V

 

 

 

 

 

 

Charge restart voltage (nominal)

12.8 V

 

 

 

 

 

 

Low battery alarm

11.0 Vdc

 

 

 

 

 

 

Low battery shutdown

10.5 Vdc

 

 

 

 

 

 

High battery voltage shutdown

15.5 Vdc

 

 

 

 

 

 

 

 

 

 

USB Section

 

 

 

 

 

 

 

Output Voltage (No Load)

5 Vdc

 

 

 

 

 

 

Output Voltage current

500mAdc

 

 

 

 

 

 

 

 

 