OF THE USER.
Installing the fan
This appliance is intended for connection to fixed wiring.
Check that the electrical rating shown on the appliance matches the mains supply.
WARNING: THIS APPLIANCE MUST BE EARTHED.
All installations must be supervised by a qualified electrician. Installation and wiring must conform to current IEE regulations (UK), local or appropriate regulations
(other countries).
If you have any queries before installing these products or after they have been installed, call the Xpelair Technical Hotline +44 (0) 8709 000430. Our engineers are there to help you during normal office hours (UK only) and may be faxed at all other times +44 (0) 8709 000530. Customers outside the UK please contact your local Xpelair distributor, details of which are available
from the UK office.
Description
The GX6 models have the following features:
●Window / wall / panel / roof mounting options.
GX6
●For remote switch operation.
●Single speed extract operation.
●Trickle ventilation setting.
GXC6
●Integral pull cord operation.
●Single speed extract operation.
●Trickle ventilation setting.
GXC6T
●Integral pull cord operation.
●Integral timer facility.
●Single speed extract operation.
●Trickle ventilation setting.
GX6T
●For remote switch operation.
●Integral timer facility.
●Single speed operation.
●Trickle ventilation setting.
GX6HT
●For remote switch operation.
●Integral humidistat / timer facility.
●Single speed operation.
●Trickle ventilation setting.
GX6HT2
●For remote switch operation.
●Integral pull cord operation.
●Integral humidistat / timer facility.
●Two speed operation.
●Trickle ventilation setting.
GXS6
●Remote switch operation.
●Single speed extract operation.
●Solenoid operated back draught shutters, for instant opening and closing.
●Trickle ventilation setting.
GX6 (IP25)
●For remote switch operation.
●Single speed extract operation.
●Trickle ventilation setting.
●IP25 ingress protection.
What the installer will need
●A means for disconnection in all poles must be provided in the fixed wiring in accordance with the wiring rules.
●If metal switch boxes are used, earthing regulations must be followed.
●The GX6, GXC6, GXC6T and GXS6 require suitably rated 3-core cable (see “Installing switches and cables” section).
●The GX6 (IP25) require suitably rated circular 3-core cable with a diameter not less than 5.5mm (see “Installing switches and cables” section).
●The GX6T, GX6HT and GX6HT2 require suitably rated 4 or 5 core cable (see “Installing switches and cables” section).
●The GX6T, GX6HT and GX6HT2 requires a wall or ceiling mounted “on /off’ switch with built-in indicator light. For external boost/triggering, two switches are required.
●6mm blade large screwdriver, 3mm blade electrician’s screwdriver and No.1 & 2 Pozidriv screwdrivers.
If window mounting the fan, you will also need:
●A single glazed window with a minimum glass thickness of 4mm or a double glazed unit with a pre- prepared sealed hole.
If wall mounting the fan, you will also need:
●Masonry drill, hammer & chisel (or core drill equipment, if available).
●Mortar (to make good the hole).
●Wall kit WK6/300 (available from Xpelair) for walls up to 300mm (12”) thick or WK6/450 (available from Xpelair) for walls up to 450mm (18”) thick.
(eg, Opposite an internal doorway). |
● Near the source of steam or odours. |
● Not where ambient temperatures |
are likely to exceed 50 degrees C. |
● If installed in a kitchen, fans must |
not be mounted immediately above |
a cooker hob or eye level grill. |
● If installing in a room containing a |
fuel burning device, which has a |
non balanced flue, it is the |
installers responsibility to ensure |
that there is enough replacement |
air to prevent fumes being drawn |
down the flue when the fan is |
operating up to maximum extract. |
Refer to Building Regulations for |
specific requirements. Exhaust air |
must not be discharged into a flue |
used for exhausting fumes from |
appliances supplied with energy |
other than electric. |
Requirements of all authorities |
concerned must be observed for |
exhaust air discharge and intake |
flow rates. |
● When intended for use in possible |
chemical corrosive atmospheres, |
consult our technical service |
department. (For overseas markets |
contact your local Xpelair |
Distributor). |
● This electrical product, if installed |
in a shower room or bathroom, |
must be situated so that it cannot |
be touched by persons making use |
of the bath or shower. |
Installing the switches and cables
1.Check that there are no buried pipes or cables (eg. electricity, gas, water) behind the switch location (in the wall or above the ceiling).
2.Lay in the cable from the isolating switch to the fan location via the on/ off switch (see Fig.E1), SW1 (see Fig.E2.) and external boost SW1 (see Fig.E3) if required.
3.Lay in the cable from the isolating switch to the point of connection to the mains supply.
WARNING: DO NOT MAKE ANY CONNECTIONS TO THE ELEC- TRICAL SUPPLY AT THIS STAGE.
4.Install the isolating switch and the on/ off switch (see Fig.E1), SW1 (see Fig.E2) and external boost SW2 (see Fig.E3) if required.
5.Make all connections within the isolating switch and the on/off switch if required.
Note: When installed in a bathroom all switches must be of a pull cord type and must be situated so that they cannot be touched by persons making use of the bath or shower.