AW1600 Owner’s Manual
MIDI data format
218
Appendix
5.13.1.5. MMC REWIND
< Transmission >
This message is transmitted with a device number of 7F when the
REWIND key is pressed.
< Reception >
If the AW1600 is operating as an MMC Slave, the transport will
begin rewind when this message is received with a matching device
number or a device number of 7F.
5.13.1.6. MMC RECORD STROBE
< Reception >
This message is received if the AW1600 is operating as an MMC
Slave and the device number matches or is 7F. If the transport is
stopped, then recording will begin. If the transport is playing, then
punch-in will occur.
5.13.1.7. MMC RECORD EXIT
< Reception >
This message is received if the AW1600 is operating as an MMC
Slave and the device number matches or is 7F. If the transport is
recording, then punch-out will occur.
5.13.1.8. MMC RESET
< Transmission >
This message is transmitted with a device number of 7F when song
loading is finished.
< Reception >
This message is received if the AW1600 is operating as an MMC
Slave and the device number matches or is 7F. MMC-related internal
settings will be reset to the power-on state.
5.13.1.9. MMC LOCATE (TARGET)
< Transmission >
This message is transmitted with a device number of 7F when a
locate-related key such as MARK SEARCH/IN/OUT is pressed, a
FF/REW operation is performed, when the transport returns to the
auto-punch pre-roll point, or when repeating.
< Reception >
This message is received if the AW1600 is operating as an MMC
Slave and the device number matches. The transport will locate to the
time code position specified within the command data.
STATUS 11110000 F0 System Exclusive Message
ID No. 01111111 7F Real Time System Exclusive
Device ID 0ddddddd dd Destination (00-7E, 7F:all call)
Command 00000110 06 Machine Control Command (mcc) sub-id
00000101 05 Rewind (MCS)
EOX 11110111 F7 End Of Exclusive
STATUS 11110000 F0 System Exclusive Message
ID No. 01111111 7F Real Time System Exclusive
Device ID 0ddddddd dd Destination (00-7E, 7F:all call)
Command 00000110 06 Machine Control Command (mcc) sub-id
00000110 06 Record strobe
EOX 11110111 F7 End Of Exclusive
STATUS 11110000 F0 System Exclusive Message
ID No. 01111111 7F Real Time System Exclusive
Device ID 0ddddddd dd Destination (00-7E, 7F:all call)
Command 00000110 06 Machine Control Command (mcc) sub-id
00000111 07 Record Exit
EOX 11110111 F7 End Of Exclusive
STATUS 11110000 F0 System Exclusive Message
ID No. 01111111 7F Real Time System Exclusive
Device ID 0ddddddd dd Destination (00-7E, 7F:all call)
Command 00000110 06 Machine Control Command (mcc) sub-id
00001101 0D Reset
EOX 11110111 F7 End Of Exclusive
STATUS 11110000 F0 System Exclusive Message
ID No. 01111111 7F Real Time System Exclusive
Device ID 0ddddddd dd Destination (00-7E, 7F:all call)
Command 00000110 06 Machine Control Command (mcc) sub-id
01000100 44 Locate
00000110 06 byte count
00000001 01 “target” sub command
0hhhhhhh hh hour (Standard Time Code)
0mmmmmmm mm minute
0sssssss ss second
0fffffff ff frame
0sssssss ss sub-frame
EOX 11110111 F7 End Of Exclusive