Using this unit

Turning off this unit

1.When you have finished using this unit, press the STANDBY/ON button.

There will be a message to confirm turning off this unit. Press

the STANDBY/ON button again to turn off this unit. The lamp

turns off and the indicator flashes in orange while the fan is rotating to cool the lamp for approximately two minutes. This unit cannot be turned back on by pressing the STANDBY/ ON button in this state.

indicator (flashes)

STANDBY/ON

 

INPUT

 

STANDBY/ON

LAMP

TEMP

PATTERN

AUTO

PATTERN

/COVER

/FAN

24P

 

 

PATT

ESCAPEMENU

SELECT

STANDBY/ON

ASPECTINPUT

RESET STILL HIDE

2.When the lamp has cooled down, the indicator stops flashing and steadily lights in red.

3.Turn off the power switch after making sure that the fan has completely stopped and that the indicator is lit in red.

Important

While the fan is rotating and the indicator is flashing in orange, never turn off the power switch or unplug this unit. This will cause significant damage to the lamp and may result in its shorter life or failure.

Indicators

There are four indicators on this unit to display the operating status of this unit.

STANDBY/ON

 

 

INPUT

 

LAMP

TEMP

PATTERN

MENU

/COVER

/FAN

 

24P

 

12 3 4

1

Off

The power is turned off.

Lights in red

In the standby mode

Flashes in green

Getting ready to start operation

Lights in green

Operating

Flashes in orange

Cooling the lamp

2LAMP/COVER

Off

Normal

Lights in red

The lamp cover is not correctly attached.

 

The air filter cover is not correctly

attached.

Flashes in red (1-second intervals)

The lamp usage has exceeded 1000 hours.

Flashes in red (0.5-second intervals)

The lamp usage has exceeded 1100 hours.

The lamp has burnt out.

3TEMP/FAN

Off

Normal

Lights in red

The temperature inside this unit is

 

abnormally high.

Flashes in red

The cooling fan is out of order.

4 24P

Lights in blue

This unit has detected the interlaced

 

signal (480i) of 24-frame/second film

 

and is converting it to progressive

 

images.

Off

Video signals other than the interlaced

 

signal (480i) of 24-frame/second film are

 

being input.

E-14