Maintenance
■Regular care
Disconnect the power cable from this unit before starting regular care. Clean the housing of this unit with a soft cloth. If heavily soiled, use a damp cloth with a mild detergent and then wipe with a dry cloth again. Do not use strong detergents or solvents such as alcohol or thinner to prevent from damaging the finish or shape of the unit. When cleaning the housing, do not directly touch or rub the lens.
■Cleaning the filter
If dust has accumulated on the filter attached in the ventilation slot, the air does not circulate well and the temperature inside this unit will rise. This may cause damage to this unit. Clean the filter every 200 hours. If you find difficulty clearing the dust, replace it with new one.
1.Turn off the power and disconnect the power cable from this unit.
2.Pull down the filter holders located on the rear of this unit. Remove the filter frame by pulling it toward you and then downward.
3.Remove the wire remains placed inside the filter frame that snaps into place behind four tabs. Then remove the thin sponge filter from both sides.
4.Carefully clean and wash the removed filters to eliminate accumulated dust.
5.After the cleaned filters are completely dry, put them back on this unit. If they are not refitted correctly, the lamp will not turn on.
Important
•If the filter is heavily soiled, replace it with the new one supplied.
•When you need more filters for replacement, contact the store where this unit was purchased.