To stop projecting:

1.Press the STANDBY/ON () button on the projector or the STANDBY () button on the remote control.

A confirmation message is displayed.

To cancel the procedure, wait a while or press the MENU button.

2.Press the STANDBY/ON () button on the projector or the STANDBY () button on the remote control again.

The lamp goes out and the projector goes into a cooling period. In this condition, the POWER indicator turns red and the STATUS indicator blinks green.

3.Wait about one minute for the STATUS indicator to be off and the POWER indicator to be steadily lit in red.

During this one minute period, the intake and exhaust fans rotate to cool the lamp.

The fan may make loud sounds during a cooling period.

Caution

Do not unplug the power cable while the STATUS indicator is blinking. Unplugging the power cable immediately after use may damage the lamp or reduce lamp life.

KEYSTONE adjustment

Use to correct vertical and horizontal image distortion caused by tilting the projector.

1.Press the KEYSTONE (ENTER) button on the control area of the projector or the KEYSTN button on the remote control.

2.Adjust the projection angle by pressing , , , buttons as shown.

To exit from the menu:

3.Press the KEYSTONE (ENTER) button on the control area of the projector or the KEYSTN button on the remote control again.

Important

Press button

Press

 

Press

button

 

button

 

Press button

When the keystone adjustment is applied, the correct aspect ratio may not be obtained.

When the keystone adjustment is applied, the resolution lowers. In addition, vertical stripes appear and straight lines bend in images with complicated patterns. To prevent such symptoms, keep the screen and the projector perpendicular to each other as much as possible.

When the keystone adjustment is applied, the distorted image may appear for a while.

The projected image may be distorted depending on the setting value of the keystone adjustment and the type of the input signals. In such cases, adjust the setting value within the range where the projected image is not distorted.

The setting value displayed at the time of the keystone adjustment may vary depending on the type of the input signal.

IRIS button

The IRIS function adjusts the contrast optically by opening and closing the lens aperture. Select OPEN to increase the brightness of the image. Select CLOSE to deepen the black level of the image while reducing the brightness.

1.Press the IRIS button on the remote control.

• The current setting appears.

IRIS : CLOSE

2.Change the setting by pressing the IRIS button again while the current setting is being displayed.

IRIS : OPEN

CONT.

BRIGHT

C.TEMP

GAMMA SHARP IRIS

SETTING

IRIS button

17