14 Indicators

This projector has two indicators, each of which shows the operation condition of the projector.

Refer to Troubleshooting for additional indication signals.

POWER indicator

STATUS indicator

STANDBY/ON button

Normal conditions

POWER

STATUS

CONDITION

NOTE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stand-by.

 

 

 

 

 

 

 

 

 

 

 

Steady red

 

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Warming up period (about 1 minute).

The STANDBY/ON button cannot be used

Steady green

Blinking green

 

until the STATUS indicator is steady green.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The projector is ready.

 

 

 

 

 

 

 

 

Steady green

Steady green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling down period (lasts under 2 minutes; normal when

Do not unplug the projector until the

 

 

 

 

 

 

 

 

shutting down).

STATUS indicator is off.

Steady red

Blinking green

 

 

 

 

 

 

 

 

 

 

 

 

Abnormal conditions

POWER

STATUS

CONDITION

SOLUTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Abnormal temperature

 

 

 

 

 

 

 

 

 

 

• The ventilation grilles are clogged with dust or dirt.

• Clean the ventilation grilles.

Steady green

 

 

 

 

 

 

 

 

 

 

 

 

• The room temperature is high.

• Relocate the projector to a cooler place.

or

 

 

 

 

 

 

Blinking orange

 

• Remove any objects blocking the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ventilation grilles.

 

 

 

 

 

 

 

 

 

 

Steady red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Abnormal when it occurs except while shutting down. The

• Wait until the STATUS indicator goes out,

 

 

 

 

 

 

 

 

 

protection circuit is working or the lamp is in an abnormal

then press the STANDBY/ON button.

Steady red

Blinking green

condition.

• If the above solution is not effective,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

replace the lamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp operation time warning. (Total lamp operation time

Replace the lamp.

 

 

 

 

 

 

 

 

 

reached 2250 hours*1 while the power was on.)

Change with a new lamp if this problem

Steady green

Blinking green/red

 

recurs.

Lamp operation time warning. (Total lamp operation time reached 2250 hours*1 while the power was off.)

Steady red

Blinking red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Lamp operation time warning. (Total lamp operation time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

reached 3000 hours*1, *2 while the power was off.)

 

Steady red

 

 

 

 

Steady red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The lamp cover isn’t closed.

Close the cover correctly.

Blinking

 

 

 

Off

 

green/red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Abnormal.

Contact your dealer.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Blinking

 

 

 

Steady or Blinking

 

green/red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1: When LAMP MODE of the SETUP menu is set to CINEMA.

 

*2: When LAMP MODE is set to STANDARD, this duration will be decreased to 2000 hours.

 