14 Indicators
This projector has two indicators, each of which shows the operation condition of the projector.
Refer to Troubleshooting for additional indication signals.
POWER indicator
STATUS indicator
STANDBY/ON button
◆Normal conditions
POWER | STATUS | CONDITION | NOTE | |||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| |
Steady red |
| Off |
|
| ||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Warming up period (about 1 minute). | The STANDBY/ON button cannot be used | |
Steady green | Blinking green |
| until the STATUS indicator is steady green. | |||||||
|
| |||||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| The projector is ready. |
| |
|
|
|
|
|
|
| ||||
Steady green | Steady green |
|
| |||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| Cooling down period (lasts under 2 minutes; normal when | Do not unplug the projector until the | |
|
|
|
|
|
|
|
| shutting down). | STATUS indicator is off. | |
Steady red | Blinking green | |||||||||
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
◆Abnormal conditions
POWER | STATUS | CONDITION | SOLUTION | ||||||||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Abnormal temperature |
| |
|
|
|
|
|
|
|
|
| • The ventilation grilles are clogged with dust or dirt. | • Clean the ventilation grilles. | |
Steady green |
|
|
|
|
|
| |||||
|
|
|
|
|
| • The room temperature is high. | • Relocate the projector to a cooler place. | ||||
or |
|
|
|
|
|
| |||||
Blinking orange |
| • Remove any objects blocking the | |||||||||
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| ventilation grilles. | |
|
|
|
|
|
|
|
|
|
| ||
Steady red |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Abnormal when it occurs except while shutting down. The | • Wait until the STATUS indicator goes out, | |
|
|
|
|
|
|
|
|
| protection circuit is working or the lamp is in an abnormal | then press the STANDBY/ON button. | |
Steady red | Blinking green | ||||||||||
condition. | • If the above solution is not effective, | ||||||||||
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| replace the lamp. | |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| Lamp operation time warning. (Total lamp operation time | Replace the lamp. | |
|
|
|
|
|
|
|
|
| reached 2250 hours*1 while the power was on.) | Change with a new lamp if this problem | |
Steady green | Blinking green/red | ||||||||||
| recurs. |
Lamp operation time warning. (Total lamp operation time reached 2250 hours*1 while the power was off.)
Steady red | Blinking red |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Lamp operation time warning. (Total lamp operation time |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| reached 3000 hours*1, *2 while the power was off.) |
|
Steady red |
|
| |||||||||||||||||||
|
| Steady red |
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| The lamp cover isn’t closed. | Close the cover correctly. |
Blinking |
|
|
| Off |
| ||||||||||||||||
green/red |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Abnormal. | Contact your dealer. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Blinking |
|
|
| ||||||||||||||||||
Steady or Blinking |
| ||||||||||||||||||||
green/red |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
*1: When LAMP MODE of the SETUP menu is set to CINEMA. |
| ||||||||||||||||||||
*2: When LAMP MODE is set to STANDARD, this duration will be decreased to 2000 hours. |
|
38