28
AUTO SETUP
T roubleshooting for auto setup procedure
Before auto setup
Errors during auto setup
Error message Cause Remedy
Connect MIC Optimizer microphone is not connected. Connect the supplied optimizer microphone to the
OPTIMIZER MIC jack on the front panel.
Unplug HP Headphones are connected. Unplug the headphones.
Error message Cause Remedy
E-1:NO FRONT SP Front L/R channel signal(s) is (are) not
detected. Select the front speakers with SPEAKERS A/B.
Check the front left and right speaker connections.
Turn on the po wer to the ex tern al amp lif ier ( whe n the
front speaker signals are output from an external
amplifier).
E-2:NO SURR. SP Only one surround channel signal is detected. Check the surround speaker connections.
E-3:NO PRES. SP Only one presence channel signal is detected. Check the presence speaker connections.
E-4:SBR->SBL Only right surround back channel signal is
detected. Connect the surround back speaker to the LEFT
SURROUND BACK SPEAKERS terminal if you
only have one surround back speaker.
E-5:NOISY Background noise is too loud. Try the auto setup procedure in a quiet environment.
Turn off nois y electric equipme nt like air cond itioners
(etc.) or move them away from the optimizer
microphone.
E-6:CHECK SUR. Surround back speaker(s) is ( are) connected,
though surround L/R speakers are not. Connect surround speakers when you use (a)
surround back speaker(s).
Check the surround speaker connections .
E-7:NO MIC The optimizer microphone was unplugged
during the auto setup procedure. Do not touch the optimizer microp hone during the
auto setup procedure.
E-8:NO SIGNAL The optimizer microphone does not detect test
tones. Check the microphone setti ng.
Check the speaker connections and placement.
E-9:USER CANCEL The auto setup procedure was cancelled due to
user activity. Perform the auto setup procedure again. Do not adjust
VOLUME (etc.) during the auto setup procedure.
E-10:INTERNAL
ERROR A DSP communication error or hangup
occurred. Perform the auto setup procedure again.