2-2 System Information

2-2-1 System Real-Time Message

Active

sensing

Status

11111110(FE)

Transmitted once approximately every 200 milliseconds

2-2-2System Exclusive Message

Transmitted only when MIDI SYS INFO is ON

(1) Parameter Change

 

Status

11110000(F0)

ID no.

01000011(43)

Substatus/ch. no.

0001 nnnn(1n) n=channel no.

Parameter group no.

00010010(12)

Parameter no.

0ppppppp

Data

0ddddddd

EOX

11110111(F7)

This data is transmitted when voice or function Parameters are changed in the EDIT or FUNCTION modes. The voice parameters transmitted are those given in voice parameter table 5-2, and the function parameters transmitted are shown in function parameter table 5-3.

(2) 1 Voice Bulk Data

 

Status

11110000(F0)

ID no.

01000011(43)

Substatus / ch. no.

0000nnnn(0n) n=channel no.

Format no.

00000011(03)

Byte count

00000000(00)

Byte count

01011101(5D)

Data

0ddddddd

 

93 bytes

 

0ddddddd

Checksum

0eeeeeee

EOX

11110111(F7)

The data for one voice is transmitted when a voice selector is pressed in the PLAY mode. Data in the voice edit buffer is transmitted when a format no. f=3 dump request is received. The transmitted data is shown in voice parameter table 5-2. The checksum is the lowest 7 bits of the two’s complement sum of all data bytes (the same applies below).

Functions not available on this unit are set as follows:

CHORUS: 0

 

 

PEG PRI=99,

PR2=99,

PR3=99

PL1=50,

PL2=50,

PL3=50

FOOT VOLUME RANGE = 99

 

(3) 32 Voice BULK Data

 

 

Status

11110000(F0)

 

ID no.

01000011(43)

 

Substatus/ch. no.

0000nnnn(0n)

n=channel no.

Format no.

00000100(04)

 

Byte count

00100000(20)

 

47