York D1EE 060 installation instructions General, Inspection, Reference, Approvals, Sunline

Models: D2EE 036 D1EE 060 D1EE 048

1 16
Download 16 pages 8.1 Kb
Page 1
Image 1
SUNLINE 2000™

J￿

SUNLINE 2000

 

 

 

 

ELECTRIC / ELECTRIC

 

SINGLE PACKAGE AIR CONDITIONERS

INSTALLATION INSTRUCTION Supersedes: 035-12046-002-A-0302

035-12046-003-A-0204

MODELS D1EE 048 & 060 and D2EE 036 (11 SEER)

GENERAL

YORK Model DEE units are single package air conditioners designed for outdoor installation on a rooftop or a slab. Electric heaters are available as field-installed accessories.

The units are completely assembled on rigid, permanently attached base rails. All piping, refrigerant charge, and electrical wiring is factory-installed and tested. The units require only electric power and duct connections at the point of installation.

The electric heaters have nickel-chrome elements and utilize single point power connection.

INSPECTION

As soon as a unit is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the carrier's freight bill. A separate request for inspection by the carrier's agent should be made in writing. Refer to Form 50.15-NM for additional information.

REFERENCE

Additional information on the design, installation, operation and service of this equipment is available in the following reference forms:

55.70-N1 -General Installation

55.70-N2 -Pre-start & Post-start Check List

530.18-N1.2V -Economizer Accessory

530.18-N1.13V -Man. Outdoor Air Damper Accy 0-35%

530.18-N1.14V -Man. Outdoor Air Damper Accy 0-100%

530.18-N1.12V -Motorized Outdoor Air Damper Accy.

530.18-N1.8V -Coil Guard

530.18-N7.1V -Electric Heater Accessory

530.18-N7.2V -Fuse Block Accessory

690.15-N25V -Low Ambient to 0°F

Renewal Parts:

Refer to Parts Manual for complete listing of replacement parts on this equipment.

All forms referenced in this instruction may be ordered from:

Standard Register

Toll Free Tel: 877-318-9675/Fax. 877-379-7920

APPROVALS

Design certified by U.L. and C.G.A. as follows:

1.For use as a cooling only unit or cooling unit with electric heat.

2.For outdoor installation only.

3.For installation on combustible material.

Installer should pay particular attention to the words: NOTE, CAUTION and WARNING. Notes are intended to clarify or make the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that per- sonal injury and/or equipment damage may result if installation procedure is not handled properly.

CAUTION

THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH

THE ENCLOSED INSTALLATION INSTRUCTIONS AND ANY APPLICABLE

LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED

TO, BUILDING, ELECTRICAL, AND MECHANICAL CODES.

WARNING

INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.

Page 1
Image 1
York D1EE 060, D1EE 048 installation instructions General, Inspection, Reference, Approvals, Sunline, Electric / Electric