035-12046-003-A-0204

TABLE 5 - SUPPLY AIR PERFORMANCE - 5 TONw/Belt-Drive Blower

5 TON GAS HEAT VALUES SHOWN @ 230/460/575 VOLTS - Side Duct Connections

UNIT

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

SIZE

0.20

0.30

0.40

0.50

0.60

0.70

0.80

CFM

(MBH)

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

2500

1059

1560

1077

1590

1095

1630

1114

1650

1134

1660

1158

1685

1181

1720

 

2400

1032

1405

1054

1470

1074

1525

1094

1560

1116

1595

1140

1620

1167

1640

 

2300

1005

1260

1024

1275

1049

1370

1069

1440

1090

1475

1116

1505

1142

1535

 

2200

980

1160

1002

1170

1022

1190

1044

1250

1066

1350

1090

1410

1117

1440

 

2100

930

1060

957

1070

983

1080

1010

1100

1039

1160

1064

1260

1092

1340

060

2000

877

950

908

975

941

1000

976

1020

1009

1050

1040

1100

1070

1225

 

1900

-

-

-

-

894

885

940

940

980

980

1014

1020

1047

1095

 

1800

-

-

-

-

855

815

903

860

950

905

988

940

1022

970

 

1700

-

-

-

-

-

-

884

815

925

850

964

880

1001

910

 

1600

-

-

-

-

-

-

864

770

908

805

948

835

987

870

 

1500

-

-

-

-

-

-

-

-

882

740

926

780

965

830

 

 

 

 

 

 

 

 

 

 

 

UNIT

AIR FLOW

 

 

 

 

Available External Static Pressure - IWG*

 

 

 

 

SIZE

0.90

1.00

1.10

1.20

1.30

1.40

1.50

CFM

(MBH)

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

RPM

Watts

 

 

2500

-

-

-

-

-

-

-

-

-

-

-

-

-

-

 

2400

1193

1665

-

-

-

-

-

-

-

-

-

-

-

-

 

2300

1170

1580

1202

1620

-

-

-

-

-

-

-

-

-

-

 

2200

1148

1480

1180

1530

-

-

-

-

-

-

-

-

-

-

 

2100

1121

1385

1155

1425

1190

1475

-

-

-

-

-

-

-

-

060

2000

1100

1285

1133

1340

1169

1385

1205

1445

-

-

-

-

-

-

 

1900

1079

1180

1110

1240

1143

1280

1178

1330

1222

1375

-

-

-

-

 

1800

1058

1060

1090

1135

1122

1190

1158

1240

1196

1295

-

-

-

-

 

1700

1035

960

1071

1030

1103

1100

1134

1140

1164

1175

1197

1205

-

-

 

1600

1020

900

1056

965

1088

1035

1118

1065

1145

1105

1170

1130

1198

1150

 

1500

1004

860

1038

880

1070

925

1101

980

1130

1045

1158

1075

1184

1110

NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95.

*INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS AND GAS-FIRED HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS.

10

Unitary Products Group

Page 10
Image 10
York D1EE 060 2500, 1560 1077, 1630, 1660, 1685, 1720, 1405 1054, 1525 1094 1560, 1595, 1620, 2300, 1260 1024, 1475, 1505

D2EE 036, D1EE 060, D1EE 048 specifications

The York D1EE 048, D2EE 036, and D1EE 060 are advanced air conditioning units designed for superior performance and energy efficiency in commercial and industrial environments. These models are part of York’s reputation for creating reliable HVAC systems that cater to a variety of applications.

The York D1EE 048 is a high-efficiency rooftop unit, renowned for its compact design and robust construction. This model boasts an integrated economizer that enhances energy savings by optimizing the use of outside air for cooling. It features a cutting-edge variable speed compressor, which provides precision cooling and reduces energy consumption under varying load conditions. The advanced microprocessor control system enables quick adjustments to system performance, further enhancing comfort and efficiency.

In contrast, the York D2EE 036 is another exemplary model, distinguished by its dual-stage heating and cooling capabilities. This unit is particularly advantageous for facilities requiring consistent temperature control throughout different seasons. With a SEER rating that meets or exceeds regulatory requirements, the D2EE 036 helps operators minimize downtime and achieve lower operational costs. Its innovative design includes a streamlined airflow system, enabling quiet operation without compromising cooling performance.

Finally, the York D1EE 060 rounds out this trio with its innovative features tailored for large-building applications. This unit is equipped with advanced inverter technology, which allows for seamless adjustments in cooling capacity based on real-time demand. The unit is designed with high-performance heat exchangers that optimize thermal transfer efficiency, ensuring rapid cooling response while maintaining low energy usage. Its smart connectivity features allow for remote monitoring and adjustments, offering facility managers enhanced control over the indoor climate.

In terms of characteristics, all three models prioritize energy efficiency, user-friendly controls, and environmentally responsible refrigerants. They comply with the latest energy standards, making them suitable for organizations aiming for sustainability. With their robust construction and user-centric features, York’s D1EE 048, D2EE 036, and D1EE 060 units represent a commitment to delivering efficient, reliable, and cutting-edge climate control solutions. Whether for small offices or large industrial spaces, these systems provide an optimal balance of performance and cost-effectiveness.