•ENTHALPY ACCESSORY CONTROL KIT - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy.
•BURGLAR BARS - Mount in the supply and return openings to prevent entry into the duct work.
•FLUE EXHAUST EXTENSION KIT - In locations with wind or weather conditions which may interfere with proper exhausting of furnace combustion products, this kit can be installed to prevent the flue exhaust from entering nearby fresh air intakes.
•CO2 SENSOR - Senses CO2 levels and automatically overrides the economizer when levels rise above the present limits.
•COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit.
•HAIL GUARD - Hail Guard kit is available to prevent unit from hail damage. This is a sloped hood that fits above the coil.
•GAS PIPING KIT - This kit supplies all necessary fittings and shut off valve.
TABLE 1: CAPACITY RATINGS - (ARI 210/240)1
MODEL | MBH | EER2 | SEER3 |
| SOUND |
CFM | RATING | ||||
|
|
|
|
| (Db)4 |
DY036 | 35.6 | 12 | 14 | 1200 | 84 |
DY048 | 46.0 | 12 | 14 | 1600 | 83 |
DY060 | 59.0 | 11.6 | 14 | 1750 | 81 |
1.80/67°F Indoor and 95°F outdoor.
2.EER = Energy Efficiency Ratio at full load - the cooling capacity in Btu’s per hour (Btuh) divided by the power input in watts, expressed in Btuh per watt (Btuh/watt).
3.SEER = Seasonal Energy Efficiency Ratio.
4.Rated in accordance with ARI 270 Standard.
TABLE 2: GAS HEAT RATINGS1
MODEL | MBH | MBH | AFUE | TEMP | |
INPUT | OUTPUT | (%) | RISE ºF | ||
| |||||
DY036N04 | 50 | 40 | 80.9 | 15 - 45 | |
DY036N08 | 100 | 80 | 80.5 | 45 - 75 | |
DY048N06 | 75 | 60 | 80.9 | 25 - 70 | |
DY048N10 | 125 | 100 | 80.3 | 45 - 75 | |
DY060N08 | 100 | 80 | 80.5 | 25 - 55 | |
DY060N10 | 125 | 100 | 80.3 | 30 - 75 |
1. All units are
TABLE 3: 2 STAGE GAS HEAT RATINGS
MODEL1 | MBH INPUT | MBH OUTPUT | STEADY STATE EFFICIENCY | RISE | MINIMUM HEATING | |||||
1ST STAGE | 2ND STAGE | 1ST STAGE | 2ND STAGE | 1ST STAGE | 2ND STAGE | MIN. | MAX. | AIRFLOW (CFM) | ||
| ||||||||||
DY036D06 | 45 | 75 | 35.8 | 60.8 | 79.4 | 81.1 | 35 | 70 | 790 | |
DY036D10 | 69 | 115 | 55.2 | 92 | 80.0 | 80.2 | 55 | 90 | 950 | |
DY048D06 | 45 | 75 | 35.7 | 60.8 | 79.4 | 81.1 | 25 | 70 | 790 | |
DY048D10 | 75 | 125 | 60.4 | 100.6 | 80.5 | 80.5 | 45 | 75 | 1230 | |
DY060D06 | 45 | 75 | 35.8 | 60.8 | 79.4 | 81.1 | 20 | 55 | 1010 | |
DY060D10 | 75 | 125 | 60.4 | 100.6 | 80.5 | 80.5 | 35 | 75 | 1230 |
1. Models are 3Ø only.
8 | Johnson Controls Unitary Products |