254892-YTG-C-0606

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

 

AIR HANDLER

 

COIL MODEL1

 

 

COOLING

 

 

 

 

ELECTRIC

 

RATED

NET MBH

 

 

MODEL

MODEL

 

W

SEER

EER

 

HEAT KW2

 

CFM

 

 

 

 

 

TOTAL

 

SENS.

 

 

 

 

 

 

 

 

 

 

 

1 PH 13 SEER AC WITH AV / SV - VARIABLE SPEED

 

 

 

 

 

H2RD018S06

AV24

 

2,5,8,10,15

17

600

18.0

 

11.7

14.00

11.50

H2RD024S06

AV24

 

2,5,8,10,15

17

800

23.2

 

16.5

14.00

11.50

H2RD030S06

AV36

 

5,8,10,15,18

21

1000

30.0

 

21.2

14.00

11.50

H2RD036S06

AV36

 

5,8,10,15,18

21

1200

35.2

 

25.0

14.00

11.50

AV/SV48

 

5,8,10,15,18,20,25

24

1200

35.8

 

25.0

13.75

11.00

 

 

 

H2RD042S06

AV/SV48

 

5,8,10,15,18,20,25

24

1400

40.5

 

29.1

14.00

11.50

H2RD048S06

AV/SV48

 

5,8,10,15,18,20,25

24

1600

47.0

 

34.7

13.50

11.00

H2RD060S06

AV/SV60

 

5,8,10,15,18,20,25

24

1800

55.0

 

39.1

13.15

11.00

 

 

 

1 & 3 PH 13

SEER AC WITH AHP / F*FP / F*FV

 

 

 

 

 

H2RD018S06

AHP18

 

2,5,8

17

650

17.7

 

12.3

13.00

11.00

AHP24

 

2,5,8,10

17

655

17.9

 

12.5

13.50

11.00

 

F*FP024

 

5,8,10

17

650

17.5

 

12.2

13.00

11.00

 

AHP24

 

2,5,8,10

17

830

23.0

 

16.8

13.00

11.00

H2RD024S06

AHP30

 

5,8,10

17

795

23.6

 

17.0

13.00

11.00

F*FP024

 

5,8,10

17

800

23.0

 

16.8

13.00

11.00

 

 

 

 

F*FP030

 

5,8,10,15

17

800

23.0

 

16.8

13.00

11.00

H2RD030S06

AHP30

 

5,8,10

17

1015

30.0

 

21.9

13.00

11.00

AHP36

 

5,8,10,15,18

17

1040

30.0

 

22.6

13.50

11.00

 

F*FP036

 

5,8,10,15,19

21

1000

29.6

 

21.3

13.00

11.00

H1RD030S(25,46)

AHP30

 

5,8,10

17

1015

29.7

 

21.7

13.00

11.00

AHP36

 

5,8,10,15,18

17

1040

29.7

 

22.4

13.50

11.00

 

F4FP036

 

5,8,10,15,19

21

1000

29.3

 

21.1

13.00

11.00

 

AHP36

 

5,8,10,15,18

17

1235

35.0

 

27.2

13.50

11.00

H2RD036S06

AHP42

 

5,8,10,15,18

21

1255

35.0

 

27.5

13.50

11.00

AHP/SHP60

 

5,8,10,15,20,25

24

1200

36.0

 

26.7

14.00

11.50

 

 

 

 

F*FP040

 

5,8,10,15

21

1200

34.8

 

25.4

13.00

11.00

 

AHP36

 

5,8,10,15,18

17

1235

34.7

 

27.0

13.50

11.00

H1RD036S(25,46)

AHP42

 

5,8,10,15,18

21

1255

34.7

 

27.3

13.50

11.00

AHP/SHP60

 

5,8,10,15,20,25

24

1200

35.7

 

26.5

14.00

11.50

 

 

 

 

F*FP040

 

5,8,10,15

24

1200

34.5

 

25.2

13.00

11.00

 

AHP42

 

5,8,10,15,18

21

1485

41.0

 

31.0

13.00

11.00

H2RD042S06

AHP/SHP48

 

5,8,10,15,20

24

1400

42.0

 

30.7

13.50

11.00

AHP/SHP60

 

5,8,10,15,20,25

24

1400

40.5

 

33.2

14.00

11.50

 

 

 

 

F*FP048

 

5,8,10,15

24

1400

41.0

 

31.0

13.00

11.00

 

AHP42

 

5,8,10,15,18

21

1485

40.0

 

30.3

13.00

11.00

H1RD042S(25,46)

AHP/SHP48

 

5,8,10,15,20

24

1400

41.0

 

30.0

13.50

11.00

AHP/SHP60

 

5,8,10,15,20,25

24

1400

39.5

 

32.5

14.00

11.50

 

 

 

 

F4FP048

 

5,8,10,15

24

1400

40.0

 

30.3

13.00

11.00

H2RD048S06

F*FV060

 

5,8,10,15,20,25

24

1600

47.5

 

36.9

13.50

11.00

AHP/SHP48

 

5,8,10,15,20

24

1675

47.0

 

36.8

13.00

11.00

 

AHP/SHP60

 

5,8,10,15,20,25

24

1600

47.0

 

36.2

13.75

11.00

H1RD048S(25,46)

AHP/SHP48

 

5,8,10,15,20

24

1675

46.0

 

36.1

13.00

11.00

AHP/SHP60

 

5,8,10,15,20,25

24

1600

46.0

 

35.5

13.75

11.00

 

 

 

H2RD060S06

F*FV060

 

5,8,10,15,20,25

24

1850

55.0

 

40.3

13.20

11.00

AHP/SHP60

 

5,8,10,15,20,25

24

1850

55.0

 

40.3

13.00

11.00

 

 

 

H1RD060S(25,46)

AHP/SHP60

 

5,8,10,15,20,25

24

1850

54.0

 

39.6

13.00

11.00

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1.G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.

2.Single phase units require single phase 2HK heaters.

= Not applicable.

10

Unitary Products Group

Page 10
Image 10
York H*RD036 THRU 060, H*RD018 THRU 060 Sens, PH 13 Seer AC with AV / SV Variable Speed, Seer AC with AHP / F*FP / F*FV