254892-YTG-C-0606

Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued)

Outdoor Unit

H2RD018S06

H2RD024S06

H2RD030S06

H2RD036S06

H2RD042S06

H2RD048S06

H2RD060S06

Required TXV

1TVM2A1

1TVM2(A,B)1

1TVM2A1

1TVM2A1

1TVM2C1

1TVM2C1

1TVM2C1

Factory R-22 Charge, lbs-oz

4 - 9

6 - 3

5 - 13

6 - 0

8 - 13

8 - 6

10 - 2

 

 

 

 

 

 

 

 

Indoor Coil1,2

 

 

TXV KIT3 - Additional Charge, Oz

 

 

F2RP/F2FP040

0

F2FP048

0

F2FP060

0*

F2FV060

0

0

G4FA030S14T2A

0

G4FA030S14T2B

1

G4FA036S14T2A

0

0

0

G4FA036S17T2A

0

G4FA036S21T2A

0

G4FA036S21T2B

1

G4FA048S17T2A

0

G4FA048S17T2C

 

0

G4FA048S21T2A

0

G4FA048S21T2C

0

G4FA060S21T2C

0

G4FA060S24T2C

0

G4FD024H14T2A

0

G4FD024H14T2B

1

G4FD024H17T2A

0

G4FD024H17T2B

 

1

G4FD030H17T2A

0

G4FD035H14T2A

0

G4FD036H17T2A

0

0

0

G4FD036H21T2A

0

G4FD042H21T2A

0

G4FD042H21T2C

0

G4FD046H17T2A

0

G4FD046H17T2C

0

G4FD048H21T2A

G4FD048H21T2C

0

0

G4FD048H24T2A

G4FD048H24T2C

0

0

G4FD060H24T2C

0

G4FD061H24T2C

0

F4FP024H06T2A

0

F4FP024H06T2B

1

F4FP030H06T2A

0

F4FP036H06T2A

F4FP040H06T2A

0

F4FP042H06T2A

0

F2FP048H06T2C

0

F2FP060H06T2C

0*

F2FV060H06T2C

0

0

FOOTNOTES:

 

 

 

 

 

 

 

1.Systems matched with furnace or air handlers not equipped with blower-off delays may require blower Time Delay Kit 2FD06700224.

2.PC coils cannot be used in downflow or horizontal applications. FC coils cannot be used in horizontal applications.

3.A TXV kit must be used with these coils to obtain system performance (2A, 2B, and 2C indicate 1TVM series).

*This loose coil match does not achieve 13 SEER.

PROCEDURES:

1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and for 15 feet of inter- connecting

line tubing.

2. Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.

3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.

4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.

Unitary Products Group

5

Page 5
Image 5
York H*RD018 THRU 060, H*RD036 THRU 060 warranty Footnotes, Procedures