254892-YTG-C-0606

Additional R-22 Charge / Orifice Size for Various Matched Systems - 1 Phase (Continued)

Outdoor Unit

H2RD018S06

H2RD024S06

H2RD030S06

H2RD036S06

H2RD042S06

H2RD048S06

H2RD060S06

Required TXV

1TVM2A1

1TVM2(A,B)1

1TVM2A1

1TVM2A1

1TVM2C1

1TVM2C1

1TVM2C1

Factory R-22 Charge, lbs-oz

4 - 9

6 - 3

5 - 13

6 - 0

8 - 13

8 - 6

10 - 2

 

 

 

 

 

 

 

 

Indoor Coil1,2

 

 

TXV KIT3 - Additional Charge, Oz

 

 

HC18A3X

0

2B + 1

HC30A3X

2A + 0

0

HC36B3X

0

0

HC42C3X

0

0

HC60C3X

0

0

HD24A3X

0

2A + 0

HD36B3X

0

0

HD48C3X

0

0

HD60D3X

0

0

AHP18B3X

0

AHP24B3X

0

2A + 0

AHP30B3X

2A + 0

0

AHP36C3X

0

0

AHP42C3X

0

AHP/SHP48D3X

0

0

AHP/SHP60D3X

0

0

0

0

AV24B3X

0

2A + 0

 

AV36C3X

0

0

AV/SV48D3X

0

0

AV/SV60D3X

0

0

0

G2FD024(S,H)14,17

0

2B + 1

G2FD030(S,H)17

0

2B + 1

G2FD035(S,H)14

0

2B + 1

G2FD036(S,H)17

2A + 0

0

0

G2FD036(S,H)21

0

G2FD042(S,H)21

0

0

G2FD046(S,H)17

0

0

G2FD048(S,H)21,24

0

0

G2FD060(S,H)24

0

G2FD061H24

0

G1HA024H14

0

2B + 1

G1HA036H14

2A + 0

0

G1HA036H17

2A + 0

0

0

G1HA048H21

0

0

0

G1HA060H24

0

0

G1HD036

0

2A + 0

0

0

G1HD048

0

G1HD060

0

0

G1NA030S17K

0

2B + 1

G1NA030S21M

0

2B + 1

G1NA036S17J

0

2A + 0

0

G1NA036S21C

0

2A + 0

0

G1NA036S17L

2A + 0

0

0

G1NA042S24W

0

G1NA048S21D

2A + 0

0

0

G1NA060S24T

0

0

G1FA/G1UA030S14

0

2B + 1

G1FA/G1UA036S14

0

2A + 0

0

G1FA/G1UA036S17,21

0

2B + 1

G1FA/G1UA048S17

0

0

G1FA/G1UA048S21

0

0

G1FA/G1UA060S21,24

0

F2RP/F2FP024

0

2B + 1

F2RP/F2FP030

2A + 0

F2RP/F2FP036

0

For Notes See Page 5.

 

 

 

 

 

 

 