PHYSICAL AND ELECTRICAL DATA - 3 PHASE

254892-YTG-C-0606

PHYSICAL AND ELECTRICAL DATA - 3 PHASE

MODEL

 

H1RD

H1RD

H1RD

 

H1RD

H1RD

H1RD

H1RD

H1RD

 

H1RD

H1RD

 

030S25

036S25

042S25

 

048S25

060S25

030S46

036S46

042S46

 

048S46

060S46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Supply Voltage

 

 

208-230V, 3φ, 60Hz

 

 

460V, 3φ, 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

Normal Voltage Range 1

 

 

187 to 252

 

 

 

 

432 to 504

 

 

Minimum Circuit Ampacity

14.3

14.3

12.4

 

21.5

23.1

6.9

9.6

6.9

 

10.3

11.3

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. Overcurrent Device Amps 2

20

20

20

 

35

40

15

15

15

 

15

15

Min. Overcurrent Device Amps 3

15

15

15

 

25

25

15

15

15

 

15

15

Compressor Type 4

 

Recip

Recip

Recip

 

ScrollB

ScrollB

Recip

Recip

Recip

 

ScrollB

ScrollB

Compressor Amps

Rated Load

10.2

10.2

8.8

 

16.0

17.3

4.9

13.5

11.8

 

7.7

8.4

Locked Rotor

72

72

72

 

115

123

45

45

45

 

50

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Crankcase Heater

 

No

No

No

 

No

No

No

No

No

 

No

No

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Motor Amps

Rated Load

1.5

1.5

1.5

 

1.5

1.5

0.7

0.7

0.7

 

0.7

0.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Diameter Inches

22

22

22

 

22

24

22

22

22

 

24

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated HP

1/4

1/4

1/4

 

1/4

1/4

1/4

1/4

1/4

 

1/4

1/4

Fan Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal RPM

850

850

850

 

850

850

850

850

850

 

850

850

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal CFM

3100

3150

3550

 

3550

3600

3100

3150

3550

 

3550

3600

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Face Area Sq. Ft.

15.72

15.72

23.60

 

24.00

27.00

15.72

15.72

23.60

 

24.00

27.00

Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

Rows Deep

1

1

1

 

1

1

1

1

1

 

2

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fin / Inches

22

22

22

 

22

22

22

22

22

 

18

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liquid Line Set OD (Field Installed)

3/8

3/8

3/8

 

3/8

3/8

3/8

3/8

3/8

 

3/8

3/8

 

 

 

 

 

 

 

 

 

 

 

 

 

Vapor Line Set OD (Field Installed)

3/4

7/8

7/8

 

7/8

1-1/8

3/4

7/8

7/8

 

7/8

1-1/8

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Charge (Lbs. - Oz.) 5

5 - 13

6 - 0

8 - 13

 

8 - 6

10 - 2

5 - 13

6 - 0

8 - 13

 

8 - 6

10 - 2

Charge Per Foot, Oz.

0.68

0.70

0.70

 

0.70

0.76

0.68

0.70

0.70

 

0.70

0.76

 

 

 

 

 

 

 

 

 

 

 

 

 

Operating Weight Lbs.

208

208

208

 

215

294

208

208

215

 

250

294

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Rated in accordance with ARI Standard 110, utilization range “A”.

2.Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.

3.Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.

4.All scrolls listed with a superscript “B” are Bristol scrolls. All scrolls listed with a superscript “C” are Copeland scrolls.

5.The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request.

CDIMENSIONS

 

Unit

Dimensions

Refrigerant Connection

 

Model

 

(Inches)

 

Service Valve Size

 

 

A1

B

C

Liquid

Vapor

A

030

27

37

27

 

3/4”

 

036

27

37

27

 

 

 

042

39

37

27

3/8”

7/8”

 

048

34

43

32

 

 

 

060

38

43

32

 

7/8”*

1. Including Fan Guard.

B

* Adapter fitting required for 1-1/8” line set.

 