254892-YTG-C-0606

COOLING PERFORMANCE DATA

AIR CONDITIONER MODEL NO.

H2RD036S06 , H1RD036S(25,46) **

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

 

FC/MC/PC/UC36

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSING

IDCFM

 

 

1000

 

 

 

 

1200

 

 

 

 

1400

 

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

 

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

 

 

T.C.

35.0

35.7

34.7

38.9

40.5

37.2

37.2

35.8

40.0

41.4

39.3

38.8

36.9

41.1

42.3

 

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

32.1

30.0

25.0

25.8

19.7

33.8

32.8

27.5

28.1

21.3

35.6

35.7

29.9

30.4

22.9

 

 

KW

2.0

2.0

2.0

2.0

2.1

2.0

2.0

2.0

2.0

2.1

2.0

2.0

2.0

2.0

2.1

 

 

T.C.

33.3

34.2

33.1

37.0

38.7

35.6

35.9

34.3

38.1

39.5

38.0

37.6

35.4

39.1

40.4

 

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

30.5

29.0

24.3

24.9

19.2

32.3

31.7

26.7

27.2

20.7

34.2

34.4

29.1

29.5

22.3

 

 

KW

2.2

2.2

2.2

2.2

2.3

2.2

2.2

2.2

2.2

2.3

2.2

2.2

2.2

2.2

2.3

 

 

T.C.

31.6

32.6

31.6

35.1

36.8

34.1

34.5

32.8

36.1

37.7

36.6

36.3

34.0

37.1

38.5

 

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

28.8

28.0

23.5

24.0

18.6

30.8

30.6

25.9

26.4

20.2

32.9

33.2

28.4

28.7

21.8

 

 

KW

2.3

2.4

2.4

2.4

2.5

2.4

2.4

2.4

2.4

2.5

2.4

2.4

2.4

2.4

2.5

 

 

T.C.

29.9

31.1

30.0

33.2

35.0

32.5

33.1

31.3

34.8

35.8

35.2

35.1

32.5

35.1

36.6

 

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

27.2

27.0

22.7

23.1

18.0

29.3

29.5

25.2

25.4

19.6

31.5

31.9

27.6

27.9

21.2

 

 

KW

2.5

2.5

2.5

2.6

2.7

2.5

2.6

2.6

2.6

2.7

2.6

2.6

2.6

2.6

2.7

 

 

T.C.

28.8

29.5

28.1

31.1

32.6

31.0

31.3

29.2

32.0

33.3

33.3

33.2

30.3

33.0

34.0

 

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

26.1

25.9

21.7

22.2

17.3

27.9

28.0

24.0

24.5

18.8

29.7

30.1

26.3

26.9

20.4

 

 

KW

2.7

2.7

2.7

2.8

2.9

2.7

2.8

2.7

2.8

2.9

2.8

2.8

2.8

2.8

2.9

 

 

T.C.

27.7

27.9

26.3

29.1

30.4

29.6

29.6

27.2

30.0

30.9

31.5

31.3

28.2

30.9

31.4

 

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

25.0

24.9

20.7

21.3

16.6

26.5

26.6

22.9

23.6

18.1

28.0

28.4

25.0

25.9

19.6

 

 

KW

2.9

2.9

2.9

3.0

3.1

2.9

2.9

2.9

3.0

3.1

3.0

3.0

2.9

3.0

3.1

 

 

T.C.

26.6

26.3

24.4

27.0

28.1

28.2

27.9

25.3

27.9

28.4

29.7

29.5

26.1

28.8

28.8

 

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

24.0

23.8

19.8

20.4

15.9

25.1

25.3

21.7

22.7

17.3

26.2

26.7

23.7

25.0

18.8

 

 

KW

3.1

3.1

3.0

3.1

3.3

3.1

3.1

3.1

3.2

3.3

3.2

3.2

3.1

3.2

3.3

NOTE: ALL CAPACITIES INCLUDE

INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

 

 

 

 

 

 

 

 

 

 

**

For three-phase, decrease T.C. by 0.3 and S.C. by 0.2.

 

 

 

 

 

 

 

 

 

 

 

 

 

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

MA12B

FC/MC36B

1.00

1.00

1.00

MA12B

G*FD036H17

1.00

1.00

1.00

AHP36

1.01

1.07

1.01

AHP42

1.01

1.08

1.01

AHP/SHP60

1.03

1.05

0.99

F*FP040

1.00

1.00

1.00

MV12B*

FC/MC36B

1.01

0.98

1.01

MV16C*

FC/MC36C

1.01

0.99

0.97

AV36*

1.01

0.99

0.97

AV/SV48*

1.03

0.99

1.00

HC36

1.01

1.01

1.01

HD36

1.03

1.05

1.03

G*FA048S17

1.00

1.00

1.00

G*FA048S21

1.00

1.00

1.00

G*FD036H17

1.00

1.00

1.00

G*FD036H21

1.00

1.00

1.00

G*FD042H21

1.03

1.05

1.03

G*FD046H17

1.00

1.00

1.00

*= Single-phase outdoor units only.

Variable Speed

Coil

T.C.

S.C.

KW

Furnace *

 

 

 

 

PV8*A12

FC/MC/PC36A

1.01

1.00

1.01

PV9*A12

FC/MC/PC36A

1.00

1.00

1.00

PV8*B16

FC/MC/PC36B

1.01

1.01

1.01

P(C,V)9*B12

FC/MC/PC36B

1.01

1.00

1.01

PV8*C16

FC/MC/PC36C

1.01

1.01

0.97

PV8*C20

FC/MC/PC36C

1.01

1.01

0.97

P(C,V)9*C16

FC/MC/PC36C

1.01

1.01

1.01

P(C,V)9*C20

FC/MC/PC36C

1.01

1.01

0.97

PV8*B16

HC36

1.03

1.05

0.99

P(C,V)9*B12

HC36

1.03

1.04

1.03

PV8*A12

HD36

1.03

1.05

1.03

PV8*B16

HD36

1.03

1.06

0.99

PV8*C16

HD36

1.03

1.06

0.99

PV8*C20

HD36

1.03

1.06

0.99

PV9*A12

HD36

1.03

1.05

1.03

P(C,V)9*B12

HD36

1.03

1.05

0.99

P(C,V)9*C16

HD36

1.03

1.06

0.99

P(C,V)9*C20

HD36

1.03

1.06

0.99

*= Single-phase outdoor units only.

20

Unitary Products Group

Page 20
Image 20
York H*RD036 THRU 060 H2RD036S06 , H1RD036S25,46, Indoor Coil Model no FC/MC/PC/UC36 Condensing, AHP36 AHP42 AHP/SHP60