Airflow Performance

Table 13: Side Duct Application

Size

 

 

Thermostat

Speed

 

 

External Static Pressure (Inch Water Gauge)

 

Mode

CFM

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

(Tons)

Input

Tap

 

 

 

Watts

Watts

Watts

Watts

Watts

Watts

Watts

Watts

Watts

 

 

 

 

 

 

 

 

 

Y1

COOL-A

600

100

122

145

169

194

221

249

279

310

 

 

Low

Y1

COOL-B

450

65

81

100

122

147

176

208

243

281

 

 

Y1

COOL-C

530

81

100

121

145

170

197

226

258

291

 

 

 

 

Cool

 

Y1

COOL-D

680

127

151

176

202

228

256

284

313

342

 

 

Y1+Y2

COOL-A

800

177

204

232

261

290

320

350

382

414

 

 

 

 

 

High

Y1+Y2

COOL-B

600

100

122

145

169

194

221

249

279

310

 

 

Y1+Y2

COOL-C

700

134

159

184

211

238

265

293

323

352

 

 

 

 

 

 

Y1+Y2

COOL-D

900

229

258

288

319

351

385

420

457

494

 

 

 

W1

HEAT-A

670

123

147

172

197

224

251

-

-

-

 

 

N036

W1

HEAT-B

730

146

172

198

225

252

280

-

-

-

 

 

W1

HEAT-C

790

173

199

227

255

284

314

-

-

-

 

 

 

024

 

 

W1

HEAT-D

850

202

230

259

289

319

351

-

-

-

(2.0)

 

 

W1

HEAT-A

940

253

281

312

344

378

-

-

-

-

 

 

N056

W1

HEAT-B

975

274

303

334

368

403

-

-

-

-

 

 

W1

HEAT-C

1000

290

319

351

385

422

-

-

-

-

 

 

 

 

Heat

 

W1

HEAT-D

1050

324

353

386

422

461

-

-

-

-

 

 

W1

HEAT-A

670

123

147

172

197

224

-

-

-

-

 

 

 

 

 

 

W1

HEAT-B

690

130

155

180

206

233

-

-

-

-

 

 

 

W1

HEAT-C

710

138

163

189

215

242

-

-

-

-

 

 

D056

W1

HEAT-D

750

155

181

207

235

262

-

-

-

-

 

 

W1+W2

HEAT-A

940

253

281

312

344

378

-

-

-

-

 

 

 

 

 

 

W1+W2

HEAT-B

970

271

300

331

364

400

-

-

-

-

 

 

 

W1+W2

HEAT-C

1000

290

319

351

385

422

-

-

-

-

 

 

 

W1+W2

HEAT-D

1050

324

353

386

422

461

-

-

-

-

 

 

 

Y1

COOL-A

900

198

233

272

313

358

406

458

512

569

 

 

Low

Y1

COOL-B

760

166

190

222

262

310

366

431

503

584

 

 

Y1

COOL-C

830

180

210

245

286

332

384

441

503

571

 

 

 

 

Cool

 

Y1

COOL-D

970

221

260

302

344

388

434

481

530

579

 

 

Y1+Y2

COOL-A

1250

361

408

454

501

548

594

640

687

733

 

 

 

 

 

High

Y1+Y2

COOL-B

1050

253

296

340

384

428

472

516

561

605

 

 

Y1+Y2

COOL-C

1150

302

348

394

439

484

528

571

615

657

 

 

 

 

 

 

Y1+Y2

COOL-D

1350

429

475

522

570

620

671

723

777

831

 

 

 

W1

HEAT-A

1200

330

377

423

469

515

560

-

-

-

 

 

N065

W1

HEAT-B

1300

394

440

487

535

583

631

-

-

-

 

 

W1

HEAT-C

1400

467

511

558

607

659

713

-

-

-

 

 

 

036

 

 

W1

HEAT-D

1500

550

590

635

686

743

804

-

-

-

(3.0)

 

 

W1

HEAT-A

1150

302

348

394

439

484

528

-

-

-

 

 

N090

W1

HEAT-B

1225

345

392

439

485

531

577

-

-

-

 

 

W1

HEAT-C

1275

377

424

471

518

565

612

-

-

-

 

 

 

 

Heat

 

W1

HEAT-D

1350

429

475

522

570

620

671

-

-

-

 

 

W1

HEAT-A

740

163

185

216

255

304

362

-

-

-

 

 

 

 

 

 

W1

HEAT-B

785

170

196

230

270

317

372

-

-

-

 

 

 

W1

HEAT-C

825

178

208

243

284

330

382

-

-

-

 

 

D090

W1

HEAT-D

870

189

223

260

301

347

396

-

-

-

 

 

W1+W2

HEAT-A

1150

302

348

394

439

484

528

-

-

-

 

 

 

 

 

 

W1+W2

HEAT-B

1220

342

389

436

482

528

573

-

-

-

 

 

 

W1+W2

HEAT-C

1280

380

427

474

521

568

616

-

-

-

 

 

 

W1+W2

HEAT-D

1350

429

475

522

570

620

671

-

-

-

 

 

 

Y1

COOL-A

1030

237

280

323

367

411

455

499

543

588

 

 

Low

Y1

COOL-B

930

192

237

282

326

369

413

455

497

539

 

 

Y1

COOL-C

1070

257

300

343

386

430

475

520

565

611

 

 

 

048

Cool

 

Y1

COOL-D

1130

289

332

375

419

463

509

555

602

649

(4.0)

 

Y1+Y2

COOL-A

1550

586

640

696

752

810

869

929

991

1053

 

 

 

 

High

Y1+Y2

COOL-B

1400

466

513

561

611

663

715

770

826

882

 

 

Y1+Y2

COOL-C

1600

630

687

745

804

864

926

988

1052

1116

 

 

 

 

 

 

Y1+Y2

COOL-D

1700

723

787

851

916

982

1049

1116

1185

-

18

Unitary Products Group

Page 18
Image 18
York R-410A dimensions Airflow Performance, Side Duct Application

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.