279550-YIM-A-0207

Table 13: Side Duct Application (Continued)

Size

 

 

Thermostat

Speed

 

 

External Static Pressure (Inch Water Gauge)

 

Mode

CFM

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

(Tons)

Input

Tap

 

 

 

Watts

Watts

Watts

Watts

Watts

Watts

Watts

Watts

Watts

 

 

 

 

 

 

 

 

 

W1

HEAT-A

1200

330

373

416

461

507

554

-

-

-

 

 

N065

W1

HEAT-B

1300

394

439

484

531

579

629

-

-

-

 

 

W1

HEAT-C

1400

466

513

561

611

663

715

-

-

-

 

 

 

 

 

 

W1

HEAT-D

1500

544

596

648

702

758

815

-

-

-

 

 

 

W1

HEAT-A

1325

412

456

503

550

599

649

-

-

-

 

 

N090

W1

HEAT-B

1400

466

513

561

611

663

715

-

-

-

 

 

W1

HEAT-C

1500

544

596

648

702

758

815

-

-

-

 

 

 

 

 

 

W1

HEAT-D

1600

630

687

745

804

864

926

-

-

-

 

 

 

W1

HEAT-A

870

168

215

261

306

350

393

-

-

-

 

 

 

W1

HEAT-B

920

188

233

278

322

366

409

-

-

-

 

 

 

W1

HEAT-C

985

216

260

303

347

391

434

-

-

-

 

 

D090

W1

HEAT-D

1050

247

290

333

376

420

464

-

-

-

 

 

W1+W2

HEAT-A

1330

415

460

506

554

603

653

-

-

-

 

 

 

048

Heat

 

W1+W2

HEAT-B

1400

466

513

561

611

663

715

-

-

-

(4.0)

 

W1+W2

HEAT-C

1500

544

596

648

702

758

815

-

-

-

 

 

 

 

 

W1+W2

HEAT-D

1600

630

687

745

804

864

926

-

-

-

 

 

 

W1

HEAT-A

1450

504

553

604

656

-

-

-

-

-

 

 

N110

W1

HEAT-B

1500

544

596

648

702

-

-

-

-

-

 

 

W1

HEAT-C

1600

630

687

745

804

-

-

-

-

-

 

 

 

 

 

 

W1

HEAT-D

1700

723

787

851

916

-

-

-

-

-

 

 

 

W1

HEAT-A

940

196

241

285

329

-

-

-

-

-

 

 

 

W1

HEAT-B

970

209

253

297

341

-

-

-

-

-

 

 

 

W1

HEAT-C

1050

247

290

333

376

-

-

-

-

-

 

 

D110

W1

HEAT-D

1100

273

315

358

402

-

-

-

-

-

 

 

W1+W2

HEAT-A

1450

504

553

604

656

-

-

-

-

-

 

 

 

 

 

 

W1+W2

HEAT-B

1500

544

596

648

702

-

-

-

-

-

 

 

 

W1+W2

HEAT-C

1600

630

687

745

804

-

-

-

-

-

 

 

 

W1+W2

HEAT-D

1700

723

787

851

916

-

-

-

-

-

Table 14: Bottom Duct Application

Size

 

 

Thermostat

Speed

 

 

External Static Pressure (Inch Water Gauge)

 

Mode

CFM

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

(Tons)

Input

Tap

 

 

 

Watts

Watts

Watts

Watts

Watts

Watts

Watts

Watts

Watts

 

 

 

 

 

 

 

 

 

Y1

COOL-A

600

100

122

145

169

194

221

249

279

310

 

 

Low

Y1

COOL-B

450

65

81

100

122

147

176

208

243

281

 

 

Y1

COOL-C

530

81

100

121

145

170

197

226

258

291

 

 

 

 

Cool

 

Y1

COOL-D

680

127

151

176

202

228

256

284

313

342

 

 

Y1+Y2

COOL-A

800

177

204

232

261

290

320

350

382

414

 

 

 

 

 

High

Y1+Y2

COOL-B

600

100

122

145

169

194

221

249

279

310

 

 

Y1+Y2

COOL-C

700

134

159

184

211

238

265

293

323

352

 

 

 

 

 

 

Y1+Y2

COOL-D

900

229

258

288

319

351

385

420

457

494

 

 

 

W1

HEAT-A

670

123

147

172

197

224

251

-

-

-

 

 

N036

W1

HEAT-B

730

146

172

198

225

252

280

-

-

-

 

 

W1

HEAT-C

790

173

199

227

255

284

314

-

-

-

 

 

 

024

 

 

W1

HEAT-D

850

202

230

259

289

319

351

-

-

-

(2.0)

 

 

W1

HEAT-A

940

253

281

312

344

378

-

-

-

-

 

 

N056

W1

HEAT-B

975

274

303

334

368

403

-

-

-

-

 

 

W1

HEAT-C

1000

290

319

351

385

422

-

-

-

-

 

 

 

 

Heat

 

W1

HEAT-D

1050

324

353

386

422

461

-

-

-

-

 

 

W1

HEAT-A

670

123

147

172

197

224

-

-

-

-

 

 

 

 

 

 

W1

HEAT-B

690

130

155

180

206

233

-

-

-

-

 

 

 

W1

HEAT-C

710

138

163

189

215

242

-

-

-

-

 

 

D056

W1

HEAT-D

750

155

181

207

235

262

-

-

-

-

 

 

W1+W2

HEAT-A

940

253

281

312

344

378

-

-

-

-

 

 

 

 

 

 

W1+W2

HEAT-B

970

271

300

331

364

400

-

-

-

-

 

 

 

W1+W2

HEAT-C

1000

290

319

351

385

422

-

-

-

-

 

 

 

W1+W2

HEAT-D

1050

324

353

386

422

461

-

-

-

-

Unitary Products Group

19

Page 19
Image 19
York R-410A dimensions Bottom Duct Application

R-410A specifications

York R-410A is a widely recognized and highly efficient refrigerant used in modern air conditioning systems. Developed as an environmentally friendly alternative to R-22, R-410A has gained popularity in the HVAC industry due to its numerous advantageous features and characteristics.

One of the main features of York R-410A is its ability to provide superior cooling performance. This refrigerant operates efficiently at both high and low temperatures, allowing systems using it to maintain optimal indoor climates even during extreme weather conditions. Its high energy efficiency ratio (EER) and seasonal energy efficiency ratio (SEER) ratings make it a preferred choice for energy-conscious consumers, resulting in lower energy bills and a reduced carbon footprint.

Technologically, York R-410A systems feature advanced compressor designs that enhance their overall reliability and performance. These compressors are often equipped with variable-speed technology, enabling them to adjust their output to match the cooling demands of the space. This not only improves comfort levels but also leads to efficient energy consumption, reducing wear and tear on the equipment over time.

Another significant characteristic of York R-410A is its non-ozone-depleting properties. Unlike its predecessor R-22, which is being phased out due to its damaging effects on the ozone layer, R-410A is designed to minimize environmental impact. Its lower global warming potential (GWP) further underscores its role in promoting sustainability within the HVAC sector.

Furthermore, York R-410A systems are engineered with enhanced safety features. The refrigerant is non-toxic and non-flammable, which makes it safer for use in both residential and commercial applications. Additionally, its high thermal stability reduces the risk of breakdown or leakage, contributing to longer system lifespans and lower maintenance costs.

In conclusion, York R-410A stands out as a cutting-edge refrigerant that combines efficiency, safety, and environmental responsibility. With its advanced technologies and remarkable characteristics, it meets the demands of modern air conditioning requirements while paving the way for a sustainable future in HVAC systems. Adopting York R-410A not only benefits individual users through improved comfort and lower energy bills but also plays a vital role in protecting our planet's ozone layer and mitigating climate change.