York R-410A Nomenclature, Installation Safety Information, Limitations, D 1 NX 036 N

Models: R-410A

1 36
Download 36 pages 24.83 Kb
Page 3
Image 3
Nomenclature

279550-YIM-A-0207

3.For installation on combustible material and may be installed directly on combustible flooring or, in the U.S., on wood flooring or Class A, Class B or Class C roof covering materials.

4.For use with natural gas (convertible to LP with kit).

This product must be installed in strict compliance with the enclosed installation instructions and any applicable local, state, and national codes including, but not limited to, building, electrical, and mechanical codes.

Improper installation may create a condition where the operation of the product could cause personal injury or property damage.

This system uses R-410A Refrigerant which operates at higher pressures than R-22. No other refrigerant may be used in this system.

Nomenclature

D 1 NX 036 N 036 06

Product Category

D = Single Package Air Conditioner

Product Generation

1 = 1st Generation

2 = 2nd Generation

Product Identifier

NX = R-410A 15 SEER

Gas Heat/Electric

Factory Installed Gas Heat

N = Single Stage

D = Two Stage

Nominal Cooling Capacity (MBH)

024 = 24,000 BTUH

048 = 48,000 BTUH

036 = 36,000 BTUH

 

Voltage Code

06 = 208/230-1-60

25 = 208/230-3-60

46 = 460-3-60

Nominal Gas Heating Output Capacity (Nominal Low Gas Heat Output Capacity)

036 = 36,000 BTUH

056 = 56,000 BTUH (36,400 BTUH)

065 = 65,000 BTUH

072 = 72,000 BTUH (46,800 BTUH)

090 = 90,000 BTUH (56,160 BTUH)

110 = 110,000 BTUH (70,200 BTUH)

Installation

Installation Safety Information

Read these instructions before continuing this appliance installation. This is an outdoor combination heating and cooling unit. The installer must assure that these instructions are made available to the consumer and with instructions to retain them for future reference.

1.Refer to the unit rating plate for the approved type of gas for this product.

2.Install this unit only in a location and position as specified on Page 5 of these instructions.

3.Never test for gas leaks with an open flame. Use commercially available soap solution made specifically for the detection of leaks when checking all connections, as specified on Pages 3 and 16 of these instructions.

4.Always install furnace to operate within the furnace's intended temperature-rise range with the duct system and within the allowable external static pressure range, as specified on the unit name/rating plate, specified on Page 17 of these instructions.

5.This equipment is not to be used for temporary heating of buildings or structures under construction.

FIRE OR EXPLOSION HAZARD

Failure to follow the safety warning exactly could result in serious injury, death or property damage.

Never test for gas leaks with an open flame. use a commercially available soap solution made specifically for the detection of leaks to check all connections. A fire or explosion may result causing property damage, personal injury or loss of life.

Limitations

These units must be installed in accordance with the following:

In U.S.A.:

1.National Electrical Code, ANSI/NFPA No. 70 - Latest Edition

2.National Fuel Gas Code, ANSI Z223.1 - Latest Edition

3.Gas-Fired Central Furnace Standard, ANSI Z21.47a. - Latest Edition

4.Local building codes, and

5.Local gas utility requirements

Unitary Products Group

3

Page 3