York E*BD-F018 THRU 060, E*BD-(T HEATING PERFORMANCE - With Air Handler Continued, BTG-H-0208

Models: E*BD-(T E*BD-F018 THRU 060 W)036 THRU 060

1 32
Download 32 pages 50.39 Kb
Page 13
Image 13

246819-BTG-H-0208

HEATING PERFORMANCE - With Air Handler (Continued)

UNIT

AIR

 

COIL1

 

 

 

ARI HEATING2

 

 

MODEL*

HANDLER

 

MODEL

 

47°F

 

 

17°F

 

HSPF

 

 

 

 

 

 

 

 

 

 

 

 

 

MBH

COP

 

KW

MBH

COP

KW

STD

 

 

1 PH

13 SEER HP WITH AV -

VARIABLE

SPEED

 

 

 

 

 

 

EABD-F018S

AV24

 

17.6

3.86

 

1.33

10.1

2.42

1.21

8.40

EABD-F024S

AV24

 

22.2

3.68

 

1.77

12.4

2.46

1.49

8.40

EABD-F030S

AV36

 

30.0

3.90

 

2.27

15.5

2.34

1.94

8.25

EABD-F036S

AV36

 

35.4

4.10

 

2.52

21.8

2.96

2.14

9.30

EABD-F042S

AV/SV48

 

41.0

3.72

 

3.27

24.2

2.64

2.71

8.75

EABD-F048S

AV/SV48

 

47.0

3.60

 

3.87

29.0

2.40

3.56

8.20

EABD-F060S

AV/SV60

 

57.0

3.58

 

4.71

34.8

2.36

4.30

8.15

 

 

1 &

3 PH HP SEER AC WITH

AHP / F*FP / F*FV

 

 

 

 

 

EABD-F018S

AHP18

 

18.0

3.66

 

1.43

10.5

2.30

1.32

8.00

F*FP024

 

17.9

3.66

 

1.43

10.4

2.30

1.32

8.00

 

 

 

EABD-F024S

AHP24

 

23.0

3.44

 

1.96

13.1

2.30

1.67

8.00

F*FP030

 

23.0

3.44

 

1.96

13.1

2.30

1.67

8.00

 

 

 

EABD-F030S

AHP30

 

29.6

3.66

 

2.48

16.1

2.22

2.14

8.00

F*FP040

 

30.0

3.66

 

2.48

16.2

2.22

2.14

8.00

 

 

 

EABD-(T,W)030S

AHP30

 

28.6

3.66

 

2.28

15.6

3.66

1.24

8.00

F*FP040

 

29.0

3.66

 

2.32

15.7

3.66

1.25

8.00

 

 

 

 

AHP36

 

33.6

3.44

 

2.91

22.4

2.50

2.37

8.50

EABD-F036S

AHP42

 

34.4

3.44

 

2.93

20.4

2.50

2.39

8.40

F*FP040

 

34.2

3.44

 

2.91

20.2

2.50

2.37

8.00

 

 

 

 

F*FP042

 

34.2

3.44

 

2.91

20.2

2.50

2.37

8.00

 

AHP36

 

33.0

3.66

 

2.64

22.0

3.66

1.76

8.00

EABD-(T,W)036S

AHP42

 

34.0

3.66

 

2.72

20.2

3.66

1.61

8.00

F*FP040

 

34.0

3.66

 

2.72

20.1

3.66

1.60

8.00

 

 

 

 

F*FP042

 

34.0

3.66

 

2.72

20.1

3.66

1.60

8.00

EABD-F042S

AHP48

 

42.0

3.56

 

3.46

25.0

2.52

2.93

8.40

EABD-(T,W)042S

AHP48

 

41.0

3.66

 

3.28

24.4

3.66

1.95

8.00

 

F*FV060

 

47.5

3.60

 

3.87

29.2

2.40

3.56

8.30

EABD-F048S

 

 

 

 

 

 

 

 

 

 

 

AHP48

 

48.0

3.44

 

4.09

29.6

2.30

3.82

8.00

 

AHP60

 

48.0

3.44

 

4.09

29.6

2.30

3.82

8.10

 

F*FV060

 

46.5

3.66

 

3.72

28.6

3.66

2.28

8.00

EABD-(T,W)048S

 

 

 

 

 

 

 

 

 

 

 

AHP48

 

47.0

3.66

 

3.76

29.0

3.66

2.32

8.00

 

AHP60

 

47.0

3.66

 

3.76

29.0

3.66

2.32

8.00

EABD-F060S

F*FV060

 

57.5

3.56

 

4.73

34.6

2.34

4.33

8.15

AHP60

 

58.0

3.46

 

4.91

35.0

2.28

4.52

8.00

 

 

 

EABD-(T,W)060S

F*FV060

 

56.5

3.66

 

4.52

34.0

3.66

2.72

8.00

AHP60

 

57.0

3.66

 

4.56

34.4

3.66

2.75

8.00

 

 

 

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.

Unitary Products Group

13

Page 13
Image 13
York E*BD-F018 THRU 060, E*BD-(T HEATING PERFORMANCE - With Air Handler Continued, BTG-H-0208, Unitary Products Group