HEATING CAPACITY - With Variable Speed Furnaces (Continued)

UNIT

VARIABLE

COIL1

 

 

ARI HEATING2

 

 

SPEED

 

 

 

 

 

 

 

MODEL

MODEL

 

47°F

 

 

17°F

 

HSPF

FURNACE

 

 

 

 

 

 

 

 

 

MBH

COP

KW

MBH

COP

KW

STD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(F,L)L8VC20

FC/MC/PC48C

41.5

3.70

3.29

24.6

2.62

2.75

8.75

 

FL9(C,V)C16

FC/MC/PC48C

41.5

3.70

3.29

24.6

2.60

2.77

8.75

 

FL9(C,V)C20

FC/MC/PC48C

41.0

3.76

3.19

24.2

2.66

2.67

8.75

EABD-F042S

 

 

 

 

 

 

 

 

 

FL9(C,V)D20

FC/MC/PC48D

41.0

3.80

3.16

24.2

2.68

2.65

8.75

 

(F,L)L8VC20

HD48

41.5

3.72

3.27

24.6

2.64

2.71

8.75

 

FL9(C,V)C16

HD48

41.5

3.70

3.29

24.4

2.60

2.77

8.75

 

FL9(C,V)C20

HD48

41.5

3.70

3.29

24.4

2.62

2.75

8.75

 

FL9(C,V)D20

FC/MC/PC60D

47.5

3.54

3.93

29.4

2.36

3.65

8.20

 

(F,L)L8VC16

FC/PC60C

47.5

3.50

3.98

29.4

2.34

3.68

8.10

 

(F,L)L8VC20

FC/PC60C

47.5

3.54

3.93

29.4

2.36

3.65

8.20

 

FL9(C,V)C16

FC/PC60C

47.0

3.50

3.93

29.6

2.34

3.71

8.15

EABD-F048S

 

 

 

 

 

 

 

 

 

FL9(C,V)C20

FC/PC60C

47.5

3.52

3.95

29.6

2.36

3.67

8.20

 

FL9(C,V)C20

HC60

47.5

3.52

3.95

29.4

2.36

3.67

8.20

 

(F,L)L8VC20

HD60

47.5

3.54

3.93

29.4

2.36

3.65

8.20

 

FL9(C,V)C20

HD60

47.5

3.52

3.95

29.6

2.36

3.67

8.20

 

FL9(C,V)D20

MC61D

47.5

3.56

3.91

29.4

2.36

3.65

8.20

 

FL9(C,V)D20

FC/MC/PC60D

56.0

3.56

4.61

34.0

2.34

4.26

8.15

 

(F,L)L8VC20

FC/PC60C

57.5

3.54

4.76

34.6

2.32

4.37

8.10

 

FL9(C,V)C20

FC/PC60C

57.0

3.52

4.83

34.2

2.32

4.32

8.10

EABD-F060S

 

 

 

 

 

 

 

 

 

FL9(C,V)D20

HC60

56.0

3.56

4.65

34.0

2.32

4.29

8.15

 

(F,L)L8VC20

HD60

56.0

3.54

4.76

34.0

2.32

4.34

8.15

 

FL9(C,V)D20

HD60

56.0

3.56

4.65

34.0

2.34

4.26

8.15

 

FL9(C,V)D20

MC61D

56.0

3.56

4.61

34.0

2.34

4.26

8.15

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

— = Not Applicable.

16

Unitary Products Group

Page 16
Image 16
York E*BD-F018 THRU 060, W)036 THRU 060, E*BD-(T warranty FC/MC/PC48C