246819-BTG-H-0208

Physical and Electrical Data - 3 Phase

MODEL

 

EABD-

EABD-

EABD-

 

EABD-

EABD-

EABD-

EABD-

EABD-

 

EABD-

EABD-

 

T030S

T036S

T042S

 

T048S

T060S

W030S

W036S

W042S

 

W048S

W060S

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit Supply Voltage

 

 

208-

230V, 3φ,

60Hz

 

 

460V, 3φ, 60Hz

 

Normal Voltage Range 1

 

 

187 to 252

 

 

 

 

432 to 532

 

 

Minimum Circuit Ampacity

12.1

14.3

14.4

 

20.2

23.1

5.6

6.9

7.2

 

9.5

11.2

Max. Overcurrent Device Amps 2

20

20

20

 

35

40

15

15

15

 

15

15

Min. Overcurrent Device Amps 3

15

15

15

 

25

25

15

15

15

 

15

15

Compressor Type

 

Recip

Recip

Recip

 

Scroll

Scroll

Recip

Recip

Recip

 

Scroll

Scroll

Compressor Amps

 

Rated Load

8.5

10.2

10.4

 

15.0

16

3.9

4.9

6.1

 

6.1

8

 

Locked Rotor

62

72

71

 

95

123

30

45

45

 

45

70

 

 

 

 

Crankcase Heater

 

 

Yes

Yes

Yes

 

No

No

Yes

Yes

Yes

 

No

No

Fan Motor Amps

 

Rated Load

1.5

1.5

1.5

 

1.5

1.5

0.7

0.7

0.7

 

0.7

0.7

Fan Diameter Inches

 

 

22

22

22

 

24

24

22

22

22

 

24

24

 

 

Rated HP

1/4

1/4

1/4

 

1/4

1/4

1/4

1/4

1/4

 

1/4

1/4

Fan Motor

 

Nominal RPM

850

850

850

 

850

850

850

850

850

 

850

850

 

 

Nominal CFM

3450

3500

3500

 

3400

3500

3450

3500

3500

 

3400

3500

 

 

Face Area Sq. Ft.

20.96

23.58

23.58

 

24.00

27.00

20.96

23.58

23.58

 

24.00

27.00

Coil

 

Rows Deep

1

1

1

 

2

2

1

1

1

 

2

2

 

 

Fin / Inches

22

22

22

 

18

18

22

22

22

 

18

18

Liquid Line Set OD

(Field Installed)

3/8

3/8

3/8

 

3/8

3/8

3/8

3/8

3/8

 

3/8

3/8

Vapor Line Set OD (Field Installed)

7/8

7/8

7/8

 

7/8

1-1/8

7/8

7/8

7/8

 

7/8

1-1/8

Unit Charge (Lbs. - Oz.) 4

8 - 7

8 - 7

8 - 7

 

12 - 8

16 - 7

8 - 7

8 - 7

8 - 7

 

12 - 8

16 - 7

Charge Per Foot, Oz.

0.70

0.70

0.70

 

0.70

0.76

0.70

0.70

0.70

 

0.70

0.78

Operating Weight Lbs.

196

208

208

 

250

294

196

208

208

 

250

294

1.Rated in accordance with ARI Standard 110, utilization range “A”.

2.Dual element fuses or HACR circuit breaker. Maximum allowable overcurrent protection.

3.Dual element fuses or HACR circuit breaker. Minimum recommended overcurrent protection.

4.The Unit Charge is correct for the outdoor unit, matched indoor coil and 15 feet of refrigerant tubing. For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. If line exceeds 25 feet, you may refer to publications software 036-68001-001 for proper line sizing.

All dimensions are in inches. They are subject to change with- out notice. Certified dimensions will be provided upon request.

 

DIMENSIONS

 

 

 

 

C

Dimensions

Refrigerant Connection

 

Unit

 

 

(Inches)

 

Service Valve Size

 

Model

A1

B

C

Liquid

Vapor

 

 

 

030

35

37

27

 

 

A

036

39

37

27

 

7/8”

042

39

37

27

3/8”

 

 

 

048

34

43

32

 

 

 

060

38

43

32

 

7/8”*

 

1.

Including Fan Guard.

 

 

 

* Adapter fitting required for 1-1/8” line set.

 

B

Unitary Products Group

5

Page 5
Image 5
York E*BD-(T, W)036 THRU 060, E*BD-F018 THRU 060 warranty Physical and Electrical Data 3 Phase, Dimensions

E*BD-(T, E*BD-F018 THRU 060, W)036 THRU 060 specifications

The York W)036 THRU 060, E*BD-F018 THRU 060, E*BD-(T series represents a significant advancement in commercial HVAC solutions, designed to meet the varied needs of large spaces that require efficient climate control. These units are particularly suited for industrial and institutional applications, where reliability and performance are paramount.

One of the main features of this series is its energy efficiency. With advanced engineering, these HVAC systems achieve a high Energy Efficiency Ratio (EER) and Seasonal Energy Efficiency Ratio (SEER), which in turn helps businesses reduce their energy bills while minimizing their environmental footprint. The systems are equipped with high-efficiency compressors and optimized refrigerant management strategies to maximize operational effectiveness.

Furthermore, the W)036 THRU 060, E*BD models are designed for flexibility in installation and integration. They can accommodate various building layouts and are compatible with multiple ventilation configurations. This adaptability makes them suitable for warehouses, educational institutions, and large retail facilities.

The technology embedded within these units is state-of-the-art. They include microprocessor-based controls that provide precise temperature management and real-time diagnostics. This smart technology facilitates easier scheduling and monitoring, allowing facility managers to optimize performance according to demand. Additionally, with features such as variable speed fan motors, these systems are able to adjust airflow based on real-time conditions, further enhancing comfort levels while saving energy.

Durability is another hallmark of the W)036 THRU 060, E*BD series. Constructed with robust materials, these units are designed to withstand the rigors of commercial use while requiring minimal maintenance. This reliability ensures that operations remain uninterrupted, which is critical for businesses that rely on consistent climate control.

In terms of environmental impact, these units adhere to stringent industry standards. They utilize eco-friendly refrigerants, which not only comply with regulations but also contribute to lower greenhouse gas emissions.

In summary, the York W)036 THRU 060, E*BD-F018 THRU 060, E*BD-(T series is a prime example of advanced HVAC technology. With features highlighting energy efficiency, flexible installation options, smart technology, and durability, these units are engineered to deliver reliable performance, making them an ideal choice for any commercial application needing superior climate control.