York E*BD-(T, W)036 THRU 060, E*BD-F018 THRU 060 warranty BTG-H-0208

Models: E*BD-(T E*BD-F018 THRU 060 W)036 THRU 060

1 32
Download 32 pages 50.39 Kb
Page 8
Image 8
Manual background

246819-BTG-H-0208

COOLING CAPACITY - With Air Handler Coils (Continued)

UNIT

AIR HANDLER

 

 

 

COOLING

 

 

 

 

 

COIL MODEL1

 

 

 

 

 

 

 

 

RATED

NET MBH

 

 

MODEL

MODEL

 

W

SEER

EER

 

 

CFM

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 PH 13 SEER AC WITH AV / SV - VARIABLE SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

EABD-F018S

AV24

 

17

600

18.0

12.6

14.00

12.00

 

 

 

 

 

 

 

 

 

 

EABD-F024S

AV24

 

17

800

23.8

16.7

14.00

12.00

 

 

 

 

 

 

 

 

 

 

EABD-F030S

AV36

 

17

1000

29.2

20.1

14.00

12.00

 

 

 

 

 

 

 

 

 

 

EABD-F036S

AV36

 

21

1200

35.0

25.2

14.00

12.00

 

 

 

 

 

 

 

 

 

 

EABD-F042S

AV/SV48

 

21

1400

41.5

30.3

14.00

12.00

 

 

 

 

 

 

 

 

 

 

EABD-F048S

AV/SV48

 

24

1600

46.5

34.8

13.75

11.00

 

 

 

 

 

 

 

 

 

 

EABD-F060S

AV/SV60

 

24

1800

55.0

39.9

13.25

11.00

 

 

 

 

 

 

 

 

 

 

 

 

 

1 & 3 PH

13 SEER HP WITH AHP / F*FP / F*FV

 

 

 

EABD-F018S

F*FP024

 

17

600

18.0

11.4

13.00

11.00

 

 

 

 

 

 

 

 

 

AHP18

 

17

600

18.0

11.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

EABD-F024S

F*FP030

 

17

800

23.2

16.4

13.00

11.00

 

 

 

 

 

 

 

 

 

AHP24

 

17

800

23.0

16.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

EABD-F030S

F*FP040

 

21

1000

28.0

19.5

13.00

11.00

 

 

 

 

 

 

 

 

 

AHP30

 

17

1000

28.4

19.5

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

 

F*FP040

 

21

1000

27.6

19.2

13.00

11.00

EABD-(T,W)030S

 

 

 

 

 

 

 

 

 

AHP30

 

17

1000

28.0

19.2

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

AHP30

 

17

1000

28.0

19.2

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

F*FP040

 

21

1200

34.6

25.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

EABD-F036S

F*FP042

 

21

1200

34.6

25.4

13.00

11.00

 

 

 

 

 

 

 

 

 

AHP36

 

21

1200

34.4

25.4

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

 

AHP42

 

21

1200

34.6

25.3

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

F*FP040

 

21

1200

34.0

24.9

13.00

11.00

 

 

 

 

 

 

 

 

 

 

EABD-(T,W)036S

F*FP042

 

21

1200

34.0

24.9

13.00

11.00

 

 

 

 

 

 

 

 

 

AHP36

 

21

1200

33.8

24.9

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

 

AHP42

 

21

1200

34.0

24.8

13.00

11.00

 

 

 

 

 

 

 

 

 

 

EABD-F042S

AHP/SHP48

 

24

1400

41.0

30.7

13.00

11.00

 

 

 

 

 

 

 

 

 

 

EABD-(T,W)042S

AHP/SHP48

 

24

1400

40.0

29.9

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

F*FV060

 

24

1600

46.0

34.6

13.50

11.00

EABD-F048S

 

 

 

 

 

 

 

 

 

AHP/SHP48

 

24

1600

46.0

35.3

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

AHP/SHP60

 

24

1600

46.0

34.6

13.25

11.00

 

 

 

 

 

 

 

 

 

 

 

F*FV060

 

24

1600

45.0

33.8

13.50

11.00

EABD-(T,W)048S

 

 

 

 

 

 

 

 

 

AHP/SHP48

 

24

1600

45.0

34.5

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

AHP/SHP60

 

24

1600

45.0

33.8

13.25

11.00

 

 

 

 

 

 

 

 

 

 

EABD-F060S

F*FV060

 

24

1800

54.0

39.7

13.25

11.00

 

 

 

 

 

 

 

 

 

AHP/SHP60

 

24

1800

55.0

39.7

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

EABD-(T,W)060S

F*FV060

 

24

1800

53.5

39.3

13.25

11.00

 

 

 

 

 

 

 

 

 

AHP/SHP60

 

24

1800

54.5

39.3

13.00

11.00

 

 

 

 

 

 

 

 

 

 

 

 

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

= Not Applicable.

Go to www.ari.org/aridirectory for the latest additional matches.

8

Unitary Products Group

Page 8
Image 8
York E*BD-(T, W)036 THRU 060, E*BD-F018 THRU 060 warranty BTG-H-0208