York YHJD18 THRU 60 warranty Accessories

Models: YHJD18 THRU 60

1 44
Download 44 pages 33.26 Kb
Page 22
Image 22

571209-YTG-C-1012

ACCESSORIES

Refer to Price Manual for specific model numbers.

Start Assist Kit (S1-2SA067*) - May be required on 24, 30, 36,

&42 models when a TXV is installed. May also be required on 18 & 60 models in low voltage application. The 48 model has factory installed start assist. See Hard Start Kit Accessory Installation Manual for Hard Start Kit part number for each model.

Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been satisfied.

Low Temperature Cutout (S1-2LT06700224) - Prevents heat pump operation below -10 °F ambient temperature.

Compressor Blanket - Designed to further reduce the normal operating sound.

TXV Kits - S1-1TVM series thermal expansion valves precisely meter refrigerant for optimum performance over a wide range of conditions. See System Charge table for TXV part number for each model.

Outdoor Thermostat (S1-2TD06700124) - Provides additional staging of supplemental electric heat.

Thermostats - Compatible thermostat controls are available through accessory sourcing. For optimum performance and installation, refer to the UPGNET “Low Voltage Wiring Diagram” document to select and apply controls.

SOUND POWER LEVEL - TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)

Size

Test Condition

63

125

250

500

1000

2000

4000

8000

dBA

SQI

 

 

 

 

 

 

 

 

 

 

 

 

18

Cooling Mode

67

71

66

69

65

59

58

55

70

19.2

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

68

70

66

68

67

61

60

57

71

19.2

 

 

 

 

 

 

 

 

 

 

 

 

 

24

Cooling Mode

68

70

67

69

72

65

66

62

75

19.0

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

69

69

63

67

67

64

65

62

72

19.1

 

 

 

 

 

 

 

 

 

 

 

 

 

30

Cooling Mode

73

70

69

71

72

66

69

63

76

19.2

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

71

73

69

71

73

68

65

62

76

19.1

 

 

 

 

 

 

 

 

 

 

 

 

 

36

Cooling Mode

72

73

71

72

73

67

66

63

76

19.0

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

70

72

69

70

71

69

65

64

75

19.2

 

 

 

 

 

 

 

 

 

 

 

 

 

42

Cooling Mode

71

71

73

73

72

67

67

64

77

19.1

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

71

71

71

72

72

69

69

65

77

19.1

 

 

 

 

 

 

 

 

 

 

 

 

 

48

Cooling Mode

72

71

68

69

66

62

57

53

71

19.1

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

71

73

70

72

70

68

65

63

75

19.1

 

 

 

 

 

 

 

 

 

 

 

 

 

60

Cooling Mode

69

69

69

70

70

65

64

63

74

19.2

 

 

 

 

 

 

 

 

 

 

 

Heating Mode

68

69

68

69

71

65

63

62

74

19.0

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated in accordance with ARI Standard 270.

22

Johnson Controls Unitary Products

Page 22
Image 22
York YHJD18 THRU 60 warranty Accessories