HEATING CAPACITY - With Air Handler (Continued)
UNIT | AIR | COIL1 |
|
|
| HEATING2 |
|
|
| ||
MODEL | HANDLER | MODEL |
| 47 °F |
|
|
|
| 17 °F |
| HSPF |
|
|
| MBH | COP | KW |
| MBH |
| COP | KW | STD |
|
| 13 SEER HP WITH AIR HANDLERS |
|
|
|
|
|
|
| ||
| AHE48D | – | 39.0 | 3.90 | 3.00 |
| 21.8 |
| 2.64 | 2.52 | 8.20 |
| AHR48D | – | 40.0 | 3.66 | 3.20 |
| 22.4 |
| 2.48 | 2.65 | 7.70 |
| AHV48D | – | 39.5 | 3.86 | 3.00 |
| 21.0 |
| 2.54 | 2.42 | 8.20 |
| AV*48 | – | 39.5 | 3.96 | 2.92 |
| 22.2 |
| 2.68 | 2.43 | 8.20 |
YHJD42S41S4 | AV*60 | – | 39.5 | 3.98 | 2.91 |
| 22.2 |
| 2.70 | 2.41 | 8.20 |
| MV16C | FC60C | 40.0 | 3.86 | 3.04 |
| 21.4 |
| 2.50 | 2.51 | 8.20 |
| MV20D | FC/MC60D | 39.5 | 3.94 | 2.94 |
| 22.2 |
| 2.66 | 2.45 | 8.20 |
| MX16C | FC60C | 40.0 | 4.08 | 2.87 |
| 22.0 |
| 2.66 | 2.42 | 8.20 |
| MX20D | FC/MC60D | 40.0 | 4.10 | 2.86 |
| 21.8 |
| 2.68 | 2.38 | 8.20 |
| AHE48D | – | 45.5 | 3.68 | 3.62 |
| 26.8 |
| 2.84 | 2.76 | 8.20 |
| AHE60D | – | 44.5 | 3.72 | 3.50 |
| 26.4 |
| 2.90 | 2.67 | 8.20 |
| AHR48D | – | 46.0 | 3.56 | 3.79 |
| 27.4 |
| 2.74 | 2.93 | 7.70 |
| AHR60D | – | 45.5 | 3.52 | 3.79 |
| 27.2 |
| 2.74 | 2.91 | 7.75 |
| AHV48D | – | 44.5 | 3.56 | 3.66 |
| 26.4 |
| 2.78 | 2.78 | 8.20 |
| AHV60D | – | 45.0 | 3.62 | 3.64 |
| 26.8 |
| 2.82 | 2.78 | 8.20 |
YHJD48S41S4 | AV*48 | – | 46.0 | 3.78 | 3.57 |
| 26.8 |
| 2.90 | 2.71 | 8.20 |
AV*60 | – | 45.5 | 3.80 | 3.51 |
| 26.8 |
| 2.94 | 2.67 | 8.20 | |
|
|
| |||||||||
| MV16C | FC60C | 45.0 | 3.70 | 3.56 |
| 26.6 |
| 2.90 | 2.69 | 8.20 |
| MV20D | FC/MC60D | 45.5 | 3.72 | 3.58 |
| 27.0 |
| 2.86 | 2.77 | 8.20 |
| MV20D | FC/MC62D | 45.0 | 3.72 | 3.54 |
| 26.6 |
| 2.90 | 2.69 | 8.20 |
|
|
|
|
|
|
|
|
|
|
|
|
| MX16C | FC60C | 45.0 | 3.80 | 3.47 |
| 26.2 |
| 2.96 | 2.59 | 8.20 |
|
|
|
|
|
|
|
|
|
|
|
|
| MX20D | FC/MC60D | 45.5 | 3.84 | 3.47 |
| 26.6 |
| 2.94 | 2.65 | 8.20 |
|
|
|
|
|
|
|
|
|
|
|
|
| MX20D | FC/MC62D | 45.5 | 3.80 | 3.51 |
| 26.4 |
| 2.94 | 2.63 | 8.20 |
| AHE60D | – | 58.0 | 3.54 | 5.01 |
| 39.0 |
| 2.76 | 4.14 | 8.20 |
| AHR60D | – | 58.0 | 3.44 | 5.28 |
| 40.0 |
| 2.68 | 4.37 | 8.15 |
|
|
|
|
|
|
|
|
|
|
|
|
| AHV60D | – | 58.0 | 3.42 | 5.18 |
| 39.0 |
| 2.68 | 4.26 | 8.15 |
YHJD60S41S5 |
|
|
|
|
|
|
|
|
|
|
|
MV20D | FC/MC62D | 58.0 | 3.52 | 5.08 |
| 39.0 |
| 2.72 | 4.20 | 8.20 | |
|
|
|
|
|
|
|
|
|
|
|
|
| MV20D | FC64D | 58.0 | 3.40 | 5.34 |
| 40.5 |
| 2.80 | 4.24 | 8.10 |
|
|
|
|
|
|
|
|
|
|
|
|
| MX20D | FC/MC62D | 58.0 | 3.58 | 4.95 |
| 38.5 |
| 2.76 | 4.09 | 8.20 |
|
|
|
|
|
|
|
|
|
|
|
|
| MX20D | FC64D | 58.0 | 3.44 | 5.20 |
| 40.0 |
| 2.86 | 4.10 | 8.15 |
1.Rated CFM same as for cooling.
2.Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
COP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
MA Modular Air Handlers use Coil Only Ratings.
— = Not Applicable.
14 | Johnson Controls Unitary Products |