York YHJD18 THRU 60 warranty Johnson Controls Unitary Products

Models: YHJD18 THRU 60

1 44
Download 44 pages 33.26 Kb
Page 21
Image 21

 

 

 

 

 

 

 

 

 

571209-YTG-C-1012

HEATING CAPACITY - With High Efficiency Motor Furnaces (Continued)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL

FURNACE

 

COIL1

 

 

 

HEATING2

 

 

 

 

 

 

°

 

 

°

 

 

HSPF

 

MODEL

 

MODEL

 

47 F

 

 

17 F

 

 

 

 

 

 

MBH

COP

KW

MBH

COP

 

KW

STD

 

 

13

SEER HP WITH HIGH

EFFICIENCY MOTOR FURNACES3

 

 

 

 

 

Y*9C*C20

 

FC/MC62D

45.5

3.56

3.74

27.2

2.78

 

2.87

8.20

 

Y*9C*C20

 

FC/PC60C

46.0

3.62

3.72

27.4

2.80

 

2.87

8.20

YHJD48S41S4

Y*9C*C20

 

UC60C

45.5

3.58

3.72

27.2

2.78

 

2.87

8.20

Y*9C*D20

 

FC/MC/PC60D

46.0

3.64

3.70

27.2

2.80

 

2.85

8.20

 

 

 

 

Y*9C*D20

 

FC/MC62D

45.5

3.60

3.70

27.2

2.80

 

2.85

8.20

 

Y*9C*D20

 

UC60D

45.5

3.60

3.70

27.0

2.78

 

2.85

8.20

 

T*(8,L)V*C20

 

FC/MC62D

58.0

3.38

5.03

39.0

2.66

 

4.30

8.15

 

T*(8,L)V*C20

 

FC64D

58.0

3.36

5.06

41.0

2.78

 

4.32

8.05

 

T*(8,L)X*C20

 

FC/MC62D

58.0

3.44

4.94

38.5

2.70

 

4.18

8.20

 

T*(8,L)X*C20

 

FC64D

58.0

3.36

5.06

39.5

2.82

 

4.10

8.10

 

T*9(C,V)*C20

 

FC/MC62D

58.0

3.36

5.06

39.0

2.64

 

4.33

8.10

 

T*9(C,V)*C20

 

FC64D

58.0

3.30

5.15

40.0

2.76

 

4.25

8.15

 

T*9(C,V)*D20

 

FC/MC62D

58.0

3.38

5.03

39.0

2.66

 

4.30

8.15

 

T*9(C,V)*D20

 

FC64D

58.0

3.30

5.15

40.0

2.76

 

4.25

8.15

YHJD60S41S5

T*9X*C20

 

FC/MC62D

58.0

3.44

4.94

38.5

2.70

 

4.18

8.20

T*9X*C20

 

FC64D

58.0

3.32

5.12

39.5

2.78

 

4.16

8.20

 

 

 

 

T*9X*D20

 

FC/MC62D

58.0

3.42

4.97

38.5

2.68

 

4.21

8.15

 

T*9X*D20

 

FC64D

58.0

3.36

5.06

40.0

2.80

 

4.19

8.20

 

Y*(8,L)C*C20

 

FC/MC62D

58.0

3.38

5.03

39.0

2.66

 

4.30

8.15

 

Y*(8,L)C*C20

 

FC64D

58.0

3.36

5.06

41.0

2.78

 

4.32

8.05

 

Y*9C*C20

 

FC/MC62D

58.0

3.36

5.06

39.0

2.64

 

4.33

8.10

 

Y*9C*C20

 

FC64D

58.0

3.30

5.15

40.5

2.74

 

4.33

8.10

 

Y*9C*D20

 

FC/MC62D

58.0

3.38

5.03

39.0

2.66

 

4.30

8.15

 

Y*9C*D20

 

FC64D

58.0

3.30

5.15

40.0

2.76

 

4.25

8.15

1.Rated CFM same as for cooling.

2.Heating MBH based on AHRI standards of 70 °F DB (Dry Bulb) entering indoor air, 72% RH (Relative Humidity) outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

3.High Efficiency Motor Furnaces have B.O.D (Blower on Delay) standard.

COP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.

— = Not Applicable.

Johnson Controls Unitary Products

21

Page 21
Image 21
York YHJD18 THRU 60 warranty Johnson Controls Unitary Products