APPENDIX
STARGATE SERIAL CONTROL ICD
The following serial port property settings must be in place in order for the host to have communication with the display.
SPEED | 19,200 BPS |
DATA BITS | 8 |
PARITY | None |
STOP BITS | 1 |
The serial control ICD commands are presented here for the user’s knowledge. The commands are written and controlled by Z Microsystems and are not intended for the customer to use. Any improper use of the commands may place the panel in an unstable state and may degrade the image quality, thereby voiding the warranty by the user.
Command Structure
The command structure for the majority of the commands for the display follow the following structure:
Z<space>U<PIP#><space><command><space><argument>
where...
“PIP#” = the
“command” = the ascii string that represents the command
“argument” = the optional argument to the command
“space” = ascii character 0x32
The command structure must be succeeded by a carriage return (0x13).
The controller returns a string of tildes (‘~’) indicating that the command has been accepted and processed. Some of the commands return other information which will be specifi ed on a per command basis.
Unless otherwise specifi ed the command strings examined in this document must be placed in the above structure when being sent to the controller.
The commands will be broken down by the image on which it operates, either the main, RGB, or NTSC image. There may be overlap between the different images and the commands that work on them.
Main Image—Standard Command Structure
The following commands operate on PIP number “0” otherwise known as the main image.
PAA
Description
PAA has the controller perform its auto adjust algorithm. This often helps the main image
49