Important! Use flexible tubing, which comply with BS.669 current edition.

A

E

BD

C

C

Warning! The gas bayonet must be in mark area.

Dimension

mm

A

250

B

680

C

50

D

250

E

580

Pressure test

The Rapid injector is used as a pressure test point.

1.Connect the pressure gauge to the Rapid injector.

2.Examine the supply pressure by turning the Rapid burner and one other burner fully on, and lighting them. The pressure must be:

a)20 mbar for Natural Gas

b)29 mbar for LPG, butane only

c)37 mbar for LPG, propane only.

3.Turn the taps off and disconnect the pressure gauge.

4.Make sure that all burners work correctly.

Checking the grill

1.Put in the grill pan containing the grid.

2.Light the grill burner by turning the grill control knob to the symbol .

3.Release the knob when the burner comes on.

Checking the hob burners

1.Lift the lid.

2.Put in the burner crowns and caps. Make sure that they are correctly seated.

3.Put in the pan supports.

4.Check each of the burners in turn by turning the burner control knob to the symbol .

5.Release the knob when the burners come on.

Checking the lid shut-off device

1.Lift the lid.

2.Light one of the hob burners.

3.Close the lid. There should be no gas supply to the hob burners. The burner goes out.

4.Turn the burner off and lift the lid. The gas supply should be restored to the hob burners, when you turn the knob on.

Checking the main oven

1.Turn the gas oven control knob to the symbol .

2.When the oven burner comes on, the gas at first flows to the oven burner slowly, at the FSD by-pass rate.

3.When the FSD heat sensor is heated sufficiently, it opens the FSD valve. The main gas stream flows to the burner.

4.After 1 minute make sure that the flame covers the full width of the burner and is stable.

5.Set the oven control knob to and close the oven door. After about 10 minutes the flame size should decrease.

6.Turn the control knob off and check that the oven flames go out.

Electrical installation

Warning! Only a qualified and competent person must do the electrical installation.

The manufacturer is not responsible if you do not follow safety precautions from chapter "Safety infor-

mation".

This appliance is supplied with a main plug and a main cable.

Connect the phases correctly, if you do not connect, spark generator will work all the time.

21

Page 21
Image 21
Zanussi ZCG551 manual Pressure test, Checking the grill, Checking the hob burners, Checking the lid shut-off device