Safety Instructions for the Installer

The mains connection must be with a cable with a plug or there must be a disconnecting device with at least 3 mm contact opening in the existing do- mestic electrical installation, which disconnects the dishwasher completely from the mains supply in accordance with NIN 2000.

In respect of fire protection, this appliance corres- ponds to type Y (EN 60 335±2±6). Only this type of appliance may be installed with a high cupboard or wall on one side.

It is not permitted to fit drawers below the cooking surface.

Protection against electric shock must be provided by the installation.

The kitchen unit in which the appliance is fitted must satisfy the requirements of DIN 68930 in re- spect of stability.

Built±in ovens and cooking surfaces are fitted with special connector systems. They may only be combined with appliances with a matching system.

All cut surfaces are to be sealed with a suitable sealant for protection against moisture.

On tiled work surfaces, the joints in the area where the hob sits on the surface must be completely fil- led with grout.

On natural, artificial stone, or ceramic tops, the snap action springs must be bonded in place.

Ensure that the seal is correctly seated in the frame and that it is seated against the work surface wi- thout leaving any gaps. Additional silicon sealant must not be applied, this will make removal more difficult in the event of the need for service.