electrolux 29
Instructions for the Installer
Installation and connection must be done in compliance with the regulations in force. Any interventions must be carried out when the appliance is switched off. Only accredited engineers may work on the appliance.
The manufacturer disclaims any liability if the safety measures are not observed.
Connecting to the electrical supply
Before connecting to the electrical supply, please make sure:
-The fuse and the domestic electrical installation must be designed for the max. load of the appliance (see rating plate).
-The domestic electrical installation must be equipped with a proper earth connection in accordance with the regulations in force.
-The socket or the
This appliance is supplied with a connection cable incorporating a standard plug, suitable for the total electric load shown on the rating plate. The plug is to be inserted into a suitable wall socket. If you require a direct connection to the electric network (mains), it will be necessary to fit between the appliance and the mains an omnipole switch, with a minimum gap between contacts of 3 mm, suitable for the required load and in compliance with rules in force. The green & yellow ground wire must not be interrupted by the switch and it should be
The mains cable and plug as supplied are to be connected to a shockproof socket (220 V~, 60 Hz). The shockproof socket must be installed in accordance with the regulations.
The following types of mains cable are suitable, taking the necessary rated cross section into account: H07
The connection cable must in any case be laid out so that at no point does it reach 50°C (over room temperature).
After the connection has been carried out, the heating elements must be tested by being operated for about 3 minutes.
Terminal block
The oven is fitted with an easily accessible terminal block which is designed to operate with a single- phase power supply of 220 V.
Letter L - | Live terminal |
Letter N- | Neutral terminal |
or E - | Earth terminal |
29