Descriptors

¥All programmed descriptors can be displayed (one at a time) by pressing and holding the READY key for 5 seconds, then releasing the key. This serves as a check for installers to be sure all descriptors are entered properly.

Event Logging

¥Event Logging feature keeps record of up to 100 events.

Access Control

¥Provides user-activated access control command which pulses a relay output for controlled opening of access doors (e.g. lobby door).

#70 End User Relay Commands

¥Allows end users to manually turn on/off relay/X-10 module outputs to control lights or other devices via keypad or phone module.

Cabinet

¥Large cabinet with removable door for easier installations.

Programming Features

¥Programming can be performed at the office prior to installation, or on the job site directly from the keypad.

¥Can be downloaded from a remote location or at the job site (using a PC/laptop with 4100SM Serial Module) by using the AdemcoÕs V-Link¨downloading software (Rev. 4 or higher) or AdemcoÕs Compass Windows downloading software.

¥The Control is pre-programmed with a set of standard values that is designed to meet the needs of many installations. These values, however, can be changed to suit the needs of any particular installation.

¥The Control can also be pre-programmed by the installer with one of four standard communication default programming values, thus further saving time and effort.

Installer Code

¥Installer code override feature. Installer code will disarm system only if it was used to arm the system.

Prohibit Program Mode Entry

¥If desired, entry to program mode via [*] + [#] within 30 seconds of power up can be disabled.

Alpha Descriptors

¥All zones and partitions can be assigned descriptions.

¥The letter "s" or " 's " can be added to descriptors.

Relay Voice Descriptors

¥Separate vocabulary for annunciating relay output descriptors when using a phone module to activate relays.

Custom Words

¥Up to 20 custom words can be added to the built-in vocabulary.

Voice Substitute Custom Words

¥Provides a means of annunciating substitute words for the phone module whenever a custom word is used for alpha keypad displays.

Downloading

¥Direct wire downloading can be done without a modem, by using a PC or Laptop computer and 4100SM Module.

#93 Menu Mode

¥Easy programming of zones using the user friendly #93 Menu Mode.

Communication Features

Communication

¥Ademco low speed, SESCOA/RADIONICS, Ademco Express, Ademco High Speed, Ademco Contact ID.

Comm. Fields

¥Easy programming for communication fields. Simply enter the report code for each zone.

Comm. Defaults

¥Communication defaults can be loaded anytime, and does not affect non-communication program fields.

Zone Reports

¥All 64 zones can report to a central station using any standard reporting format.

Callback

¥ Callback defeat option for downloading.

Real-Time Clock

¥Real-Time clock for time related functions.

NOTE: 6139 or 6139AV alpha keypad must be used to set clock, or it can be set using Downloader software.

AC Loss Reporting

¥Random AC Loss and AC Restore reporting option sends report randomly from 10-40 minutes after AC loss, to help prevent central stations from receiving an overload of reports due to area blackouts.

Test Reporting

¥Intelligent test reporting option means test reports will not be sent if any other report was sent within the programmed test report interval.

Split/Dual Reporting

¥ Split/Dual reporting communicator options available.

Cancel Report

¥Option to allow a cancel report to be sent, even after Bell Time-out has ended.

Voltage Triggers

¥Used to interface with LORRA or other devices.

¥PC Downloader can command output voltage triggers to pulse on for 2 seconds.

Phone Numbers

¥Primary and secondary phone number capability.

¥Can program different formats for each phone number.