COMMUNICATION DEFAULTS for LOW SPEED FORMAT (*94 then *80)

*45

PRIMARY FORMAT

0 Ê

Ademco Low Speed

*51

DUAL REPORTING

 

 

0 Ê

no

*46

LOW SPEED FORMAT (Primary) 0 Ê

Ademco Low Speed

*52

STANDARD/EXPANDED REPORT FOR PRIMARY

*47

SECONDARY FORMAT

0 Ê

Ademco Low Speed

 

0 Ê

0 Ê

0 Ê

0 Ê

0 Ê

0 Ê

standard

*48

LOW SPEED FORMAT (Sec.)

0 Ê

Ademco Low Speed

 

Alarm

Rstr

Bypass

Trbl

Opn/Cls

Low Bat

*53

STANDARD/EXPANDED REPORT FOR SECONDARY

*49

CHECKSUM VERIFICATION

0 Ê

0 Ê

 

0 Ê

0 Ê

0 Ê

0 Ê

0 Ê

0 Ê

standard

 

No checksum

Primary

Secondary

 

 

 

Alarm

Rstr

Bypass

Trbl

Opn/Cls

Low Bat

*50

 

 

 

 

SESCOA/RADIONICS SELECT

0 Ê

Radionics

 

 

 

 

 

 

 

 

ALARM REPORT CODE & ID DIGITS FOR ZONES 1-32 & SUPERVISORY & RESTORE CODES

*54 CODE

*55 ID

*56 CODE

1

Ê01Ê

 

Ê00Ê

 

9

Ê03Ê

 

 

 

 

 

 

 

 

 

2

Ê03Ê

 

Ê00Ê

 

10

Ê03Ê

 

 

 

 

 

 

 

 

 

3

Ê03Ê

 

Ê00Ê

 

11

Ê03Ê

 

 

 

 

 

 

 

 

 

4

Ê03Ê

 

Ê00Ê

 

12

Ê03Ê

 

 

 

 

 

 

 

 

 

5

Ê03Ê

 

Ê00Ê

 

13

Ê03Ê

 

 

 

 

 

 

 

 

 

6

Ê03Ê

 

Ê00Ê

 

14

Ê03Ê

 

 

 

 

 

 

 

 

 

7

Ê03Ê

 

Ê00Ê

 

15

Ê03Ê

 

 

 

 

 

 

 

 

 

8

Ê03Ê

 

Ê00Ê

 

16

Ê03Ê

 

*57 ID

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

*58

Ê09Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

 

*59 CODE

*60 ID

*61 CODE

*62 ID

Alarm Rst.

17

Ê03Ê

 

Ê00Ê

 

25

Ê03Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

Trouble

18

Ê03Ê

 

Ê00Ê

 

26

Ê03Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

Trble Rst.

19

Ê03Ê

 

Ê00Ê

 

27

Ê03Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

Bypass

20

Ê03Ê

 

Ê00Ê

 

28

Ê03Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

Bypss Rst.

21

Ê03Ê

 

Ê00Ê

 

29

Ê03Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

 

22

Ê03Ê

 

Ê00Ê

 

30

Ê03Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

 

23

Ê03Ê

 

Ê00Ê

 

31

Ê03Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

 

24

Ê 0 3 Ê

 

Ê00Ê

 

32

Ê03Ê

 

Ê00Ê

 

*63

Ê09Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Alarm Rst.

Trouble

Trble Rst.

Bypass

Bypss Rst.

ALARM REPORT CODE & ID DIGITS FOR ZONES 33-64 & SUPERVISORY & RESTORE CODES

*64 CODE 33 Ê03Ê

34 Ê03Ê

35 Ê03Ê

36 Ê03Ê

37 Ê03Ê

38 Ê03Ê

39 Ê03Ê

40 Ê03Ê

*65 ID

*66 CODE

Ê00Ê

 

41

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

42

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

43

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

44

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

45

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

46

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

47

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

48

Ê01Ê

 

*67 ID

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

*68

Ê09Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

*69 CODE

Alarm Rst.

49

Ê01Ê

 

 

 

Trouble

50

Ê01Ê

 

 

 

Trble Rst.

51

Ê01Ê

 

 

 

Bypass

52

Ê01Ê

 

 

 

Bypss Rst.

53

Ê01Ê

 

 

 

 

54

Ê01Ê

 

 

 

 

55

Ê01Ê

 

 

 

 

56

Ê03Ê

*70 ID

*71 CODE

Ê00Ê

 

57

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

58

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

59

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

60

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

61

Ê03Ê

 

 

 

 

 

 

Ê00Ê

 

62

Ê02Ê

 

 

 

 

 

 

Ê00Ê

 

63

Ê02Ê

 

 

 

 

 

 

Ê00Ê

 

64

Ê03Ê

 

*72 ID

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

*73

Ê09Ê

Ê00Ê

Ê00Ê

Ê00Ê

Ê00Ê

Alarm Rst.

Trouble

Trble Rst.

Bypass Bypss Rst.

ALARM REPORT CODE & ID DIGITS FOR RF RCVRs & PANICS, & THEIR SUPV. & RESTORE CODES

*74 CODE

*75 ID

*76 CODE

*77 ID

*78

 

SYSTEM NON ALARM CODES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*81

 

*82

 

 

 

 

 

 

87

Ê07Ê

 

 

Ê00Ê

 

89

 

Ê07Ê

 

 

Ê00Ê

 

 

 

Ê09Ê

Alarm Rst.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

First Digit Second Digit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Second digit of each

 

88

Ê07Ê

 

 

Ê00Ê

 

90

 

Ê07Ê

 

 

Ê00Ê

 

 

 

Ê00Ê

Trouble

Close

 

Ê00Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

code applies only to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91

 

Ê07Ê

 

 

Ê00Ê

 

 

 

Ê00Ê

Trble Rst.

 

 

 

 

 

 

 

 

4+2 or expanded (fields

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open

 

Ê00Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*52 & *53) formats.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Duress

Ê02Ê

 

 

Ê00Ê

 

 

 

Ê00Ê

Bypass

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Battery

 

Ê00Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

93

 

Ê07Ê

 

 

Ê00Ê

 

 

 

Ê00Ê

Bypss Rst.

Low Bat Res.

 

Ê00Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

97

 

Ê07Ê

 

 

Ê00Ê

 

 

 

 

 

 

AC Loss

 

Ê00Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

95

 

Ê02Ê

 

 

Ê00Ê

(1 + * or A key)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC Restore

 

Ê00Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

96

 

Ê02Ê

 

 

Ê00Ê

(3 + # or C key)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test

 

Ê00Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

99

 

Ê02Ê

 

 

Ê00Ê

(* + # or B key)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

Ê00Ê

 

Ê00Ê

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES: 97= Poll Loop Short; 88 & 90 = RCVR not receiving transmitter

Cancel

 

Ê00Ê

 

Ê00Ê

 

 

 

 

 

 

signals. 89 & 91 = RCVR not responding, bad conn. to panel.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Prog. Tamper

 

Ê00Ê

 

Ê00Ê

 

 

 

 

 

 

87 = 4285 phone module. 93 = VIM fail

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE TYPE RESTORE ENABLES

 

 

 

 

 

ARM STAY & TIME SET REPORT CODES

 

*79

ZONE TYPES 1-8 All enabled

 

 

 

 

 

 

 

 

 

1 *4 0

 

1 *4 1

 

 

 

 

 

1 Ê

 

1 Ê

 

1 Ê

 

1 Ê

 

1 Ê

 

1 Ê

 

1 Ê

 

1 Ê

 

 

 

 

 

 

First Digit

Second Digit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Armed STAY

 

Ê00Ê

 

 

Ê00Ê

 

 

 

 

1

2

 

3

 

 

 

4 5

 

 

6 7

8

 

 

 

 

 

*80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE TYPES 9 &10

 

 

 

1 Ê

 

 

1 Ê

 

 

Time/Date set or event log reset

 

Ê00Ê

 

 

Ê00Ê

 

 

 

 

 

 

 

All enabled

 

 

 

 

 

ÊÊÊ9

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ð 77 Ð

Page 77
Image 77
Guardian Technologies VISTA-40, N7001V2 Communication Defaults for LOW Speed Format *94 then *80, 77 Ð