Partition-Specific Field Descriptions (continued)

*29

Quick Arm

 

 

Enter 1 to enable arming of the burglary system in AWAY, STAY, INSTANT or

 

 

 

 

 

MAXIMUM modes by using the # key instead of the security code. When armed,

 

 

 

 

 

reports closing as User 0 if open/close reporting for User #2 (typically a master

 

 

 

 

 

level user) was enabled for a given partition. If quick arm is used, the installer code

 

 

 

 

 

and authority level 5 code cannot disarm the system. Enter 0 if Quick Arm is not

 

 

 

 

 

desired. In either case, the security code must always be used to disarm the

 

 

 

 

 

system.

* 3 2

Primary

 

 

Enter a 3 or 4 digit (depending on report format) primary subscriber account

 

Subscriber

Acct

#

number 00-09; B-F (11-15). Each number requires a 2-digit entry so as to allow

 

 

 

 

 

entry of hexadecimal digits (B-F). If a 3 digit account number is to be used, only

 

 

 

 

 

enter data in the first 3 locations, leaving the last one unfilled, by entering a *.

* 3 8

Prevent Zone XX

Entering a zone number (01-64) prevents that zone from being bypassed by the

 

Bypass

 

 

user. Enter 00 if this feature is not desired (all zones can be bypassed). This does

 

 

 

 

 

not affect fire zones, which the system prevents from being bypassed.

* 3 9

Open/Close

Report

Enter 1 if open/close reporting for the installer is desired. Otherwise enter 0

 

For

Installer

Code

 

(disable).

* 8 4

Swinger

 

 

This option limits the number of messages (Alarms or Troubles) sent for a specific

 

Suppression

 

channel in an armed period (Swinger Suppression). Enter 01-15. If 00 is

 

 

 

 

 

selected, all Alarm or Trouble codes are reported. Must be 00 (disabled) for UL.

* 8 5

Enable Dialer

 

Enter 1 for each panic/duress for which reporting is desired. Otherwise enter 0

 

For Panics &

 

(disable).

 

Duress

 

 

 

* 8 7

Entry Warning

 

Enter 0 for 3 short beeps, or 1 for slow beeps that continue for the entire entry

 

 

 

 

 

delay period.

* 8 8

Burg. Alarm

 

Enter 0 for no delay on burglary alarm communication, or 1 for 16-second delay

 

Comm. Delay

 

(no delay on 24-hour reports).

* 9 0

Secondary

 

 

Enter the 3 or 4 digit number (depending on report format) for the secondary

 

Subscriber

Acct

#

subscriber account, 00-09; B-F (11-15). Each number requires a 2-digit entry so

 

 

 

 

 

as to allow entry of hexadecimal digits (B-F). If a 3-digit number is to be used, only

 

 

 

 

 

enter data in the first 6 locations, leaving the last two unfilled. Default=15 15 15

 

 

 

 

 

15. Erase the field by entering *90*. NOTE: This field must be programmed if a

 

 

 

 

 

secondary phone number is used (field *34). This account number can be the

 

 

 

 

 

same as the primary account number.

2nd Page

Fields

 

 

 

1 * 4 3 Permanent

 

 

Enter 1 if it is desired that backlighting for the keypad display remain on at all times.

 

Keypad

 

 

Enter 0 if the display should remain unlit unless a key is pressed. The backlighting

 

Backlighting

 

then turns off again after a period of keypad inactivity. Note that when a key is

 

 

 

 

 

pressed, display backlighting turns on for all keypads in that partition.

1 * 4 5

Exit Delay

 

 

Enter 1 if beeps from the keypads during exit delay is desired. Enter 0 for no

 

Sounding

 

 

keypad sound during exit delay.

1 * 4 7

Chime On

 

 

Enter 1 for chime annunciation using the external alarm sounder. If not desired,

 

Ext. Siren

 

 

enter 0.

1 * 5 2

Send Cancel

 

Enter 1 if no report restriction is desired. Enter 0 if cancel reports are to be sent

 

If Alarm + OFF

 

within Bell Timeout period only.

1 * 7 6

Access Control

 

The system can be programmed to provide user activated access control. If

 

Relay

 

 

enabled, the assigned relay will pulse for 2 seconds when the user enters his

 

 

 

 

 

code and presses "0". Enter the relay number (00-08) for the relay that will be

 

 

 

 

 

used for access control. Enter 00 if not used in this partition.

3rd Page

Fields

 

 

 

2 * 1 8

Enable GOTO

 

Enter 1 if this partition is to be accessed by a GOTO command. Otherwise enter

 

For

This Partition

0 .

2 * 2 0 Enable

 

 

0=disable for displayed partition; 1=enable for displayed partition

 

J7

Triggers

 

 

 

 

By

Partition

 

 

Ð 54 Ð

 

 

 

 

 

Page 54
Image 54
Guardian Technologies N7001V2 Quick Arm, Subscriber Acct, Prevent Zone, Bypass, Swinger, Suppression, Enable Dialer, Relay