Dialer Options (continued)

*8 0 Zone Type Restores

For Types 9-10

*8 1 - * 8 2 Non-Alarm Report Codes

*8 9 Restore

Report Timing

2ND PAGE FIELDS

1*33 Touch-Tone W/Rotary Backup

1*34 Comm. Split Report Selection

1 * 4 0 - 1 * 4 1 Arm Stay ÊÊ& Time Set Report Ê Ê C o d e s

Enter 1 to enable restore reporting for individual zone types. Enter 0 if no restore report is desired for a zone type.

Enter the appropriate report codes as indicated on the programming form.

Enter 0 for instant restore report, as zone restores. Enter 1 for reporting after bell timeout if zone restored. Enter 2 for restore report when system is subsequently disarmed

Enter 1 to enable Rotary back-up dialing if communicator was not successful on dialing using touch-tone DTMF on first attempt. Enter 0 if this option is not be to be used.

This field allows certain reports to be directed to either the primary or secondary phone number. Enter 0, 1, or 2, in accordance with the following: 0 = split reporting disabled; 1 = alarm, alarm restore & cancel reports sent to primary Telco number, all others to secondary Telco number; 2 = open/close & test reports sent to secondary Telco number and all other reports to primary. See *51 for split/dual reporting comments.

Enter the appropriate code as shown on the programming form.

Wireless Options

1 * 2 8

RF TX Low

Enter 0 if audible beep and display annunciation upon RF transmitter low battery

 

Battery

Sound

condition is desired only in disarmed state. Enter 1 if audible beep and display is

 

 

 

desired in both armed and disarmed states. Must be 1 for UL.

1 * 2 9

RF TX Low

Enter 1 if a trouble message for RF transmitter low battery conditions is to be sent

 

Battery Report

to the central station. Enter 0 if no report for transmitter low battery is desired.

 

Enable

 

Note that a trouble message will be sent for a transmitter supervision failure

 

 

 

independent of this selection. Must be 1 for UL.

1 * 3 0

RF Rcvr

 

Enter the check-in monitoring interval in 2-hour increments. Enter 02-15times 2

 

Supervision

hours (4-30 hours). Failure of a receiver to receive any RF signal within the time

 

Check-In

Interval

entered will result in activation of the response type programmed for zone 90 for

 

 

 

the first receiver and zone 88 for the second receiver and their related

 

 

 

communication reports. Enter 00 to disable receiver supervision. Max. "6" (12 hr)

 

 

 

for UL.

1 * 3 1

RF Transmitter

Enter the check-in monitoring interval in 2-hour increments; enter 02-15times 2

 

Check-In

Interval

hours (4-30 hours). Failure of an individual transmitter to send a supervision signal

 

 

 

within the time entered will result in a trouble response and related

 

 

 

communication report. Entry 00 disables transmitter supervision. Max. "6" (12 hr)

 

 

 

for UL.

1 * 3 2

Receiver

Type

Enter 1 if using 4281 series receivers. enter 2 if using 5881 series receivers.

 

 

 

0 = none.

1 * 4 4

Wireless

Keypad

Enter 1 to enable tamper detection on wireless keypad. Enter 0 if tamper

 

Tamper Detect

detection is not desired. If this feature is enabled, any attempt to tamper by

 

 

 

means of many trial entries at a wireless keypad will be blocked by the control

 

 

 

panel. If more than 40 key depressions are received without a valid sequence

 

 

 

(arm, disarm, etc.), the Control panel will disable the wireless keypad. The inhibit is

 

 

 

removed once a valid key sequence is received from a wired keypad.

1 * 4 8

Wireless

Keypad

Enter the partition in which the RF keypad is used, 1-2. Enter 0 if no RF keypad

 

Assignment

is used.

1 * 4 9

Suppress

TX

Enter 1 to disable trouble sounding for transmitter check-in failure. Enter 0 if

 

Supervision

audible trouble sounding is desired. Must be "0" for UL.

 

Sound

 

 

 

 

 

Ð 51 Ð

Page 51
Image 51