Serial Number Enrolling/Deleting

SERIAL # PROG? 0=NO 1=YES

ENTER ZONE NO. 00=QUIT

10PROG AS RF: 2 A000-5372: 2

DELETE S/N? 0=NO, 1=YES

INPUT TYPE INPUT = 0 OR 3Ð6

LEARN S/N? 0=NO, 1=YES

INPUT S/N:L

Axxx - xxxx:L

10PROG AS RF:2 A000-5372:2

10 ZT P RC IN:L

To enroll or delete a device's serial number, enter 1 (yes). Enter 0 to move to the Alpha Programming menu.

Enter the zone number of the device to be enrolled or deleted. Press [*] to move to the next prompt. Enter 00 to quit Serial Number programming.

If the device for that zone number was not programmed as a serial number input device in the Zone Programming menus, a prompt indicating such will appear. Press [*] to return to the Enter Zone No. prompt.

If a serial number has already been enrolled for that device, a summary prompt will appear displaying the type of device and its serial number. Press [*] to continue to the Delete S/N prompt.

Enter 1 to delete the displayed serial numbered device. Enter 0 if this device should not be deleted.

If a serial number for that device has not been enrolled yet, and if the device assigned to that zone number has been programmed as a serial number input device in the Zone Programming menus, this prompt will appear. Enter the device input type as follows: 0 = none, 3 = supervised RF transmitter, 4 = unsupervised RF transmitter, 5 = RF button type, 6 = serial polling loop device. Press [*] to move to the next prompt.

If adding a new serial number device to the system, this prompt will appear after entering the input type.. Enter 1 to have the system enroll the device's serial number. To enroll the serial number at a later time but retain the zone programming information, enter 0. If 0 is entered, a zone summary screen appears (described later). Press [*] to return to the Enter Zone No. prompt to enroll another device's serial number or to exit enroll menus.

If 1 was entered at the Learn S/N? prompt, this screen will appear. The device's serial number can be manually entered as described in the Zone Programming section on the previous page, or it can be automatically enrolled by faulting the device at least twice (causing 2 transmissions). Two matching transmissions must be received. The keypad will beep with each transmission received. Press [*] to continue.

A summary screen will appear if the serial number was successfully enrolled. Press [*] to continue.

A summary screen for the zone programming will appear showing the zone number, zone type (ZT), partition assignment (P), report code (RC), and input device type (IN:L). Press * to continue. The Enter Zone No. prompt will appear again.

Ð 58 Ð

Page 58
Image 58
Guardian Technologies N7001V2, VISTA-40 Serial # PROG? 0=NO 1=YES Enter Zone no =QUIT, Zt P Rc Inl, 58 Ð