Guardian Technologies VISTA-40, N7001V2 An input type of RF, UR, BR, or SL if serial polling loop

Models: N7001V2 VISTA-40

1 122
Download 122 pages 53.89 Kb
Page 119
Image 119

00PROG AS BR:3 A123-4567 3

TE CHNO L O GY TYP E

WIRE L E S S 0

Default

In this example, the serial number is A123-4567. Once enrolled, the upper left-hand button of the program tool can be pressed to ready the system for enrolling a transmitter into the system.

The serial number for the program tool will only remain in the system until the programming mode is exited. (Entering 97 will not delete the tool.)

Press [] to continue.

Pressing the # key on the keypad will cause the system to back up to the "PROGRAM TOOL ?" prompt.

4.Enter the type of device(s) to be enrolled as follows:

0 = Wireless (Default)

1 = Polling Loop

2 = Both

Press [] to continue.

 

 

E NTE R ZN NO .

 

 

5. Enter the first zone number to be enrolled (e.g., zone 10).

 

 

 

 

 

 

 

(0 0 = Q UIT)

1 0

 

Press [] to continue.

 

 

 

 

 

 

The system will, starting with this zone number, search for the first device

 

 

 

 

 

 

 

 

Zone Number Entered

 

 

 

 

 

 

 

 

which has all of the following attributes pre-programmed in Zone

 

 

 

 

 

 

Programming:

 

 

 

 

 

 

a ) An input type of RF, UR, BR, or SL (if serial polling loop

 

 

 

 

 

 

devices enabled) programmed

 

 

 

 

 

 

b ) A loop number programmed

 

 

 

 

 

 

c ) No serial number programmed

 

 

 

 

 

 

 

 

 

 

 

 

 

If the first zone number entered does not have one or more of the above

 

 

 

 

 

 

attributes, the system will search its database for the first zone that does and

 

 

 

 

 

 

will display it on the next screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

6. This prompt is displayed when the system has found the next zone which

 

 

10 INPUT S/N

 

 

 

 

 

 

needs to be enrolled. The system will respond to the first serial number

 

 

Axxx xxxx

 

 

 

 

 

 

transmitted after the [] key on the keypad or the button of the program

 

 

 

 

 

 

 

 

 

 

 

 

tool is pressed. A single short beep will verify that the button has been

 

 

 

 

 

 

 

 

 

 

 

 

pressed. A serial number may be enrolled by one of two methods:

 

 

 

 

 

 

a) Enter the 7 digit serial number printed on the device.

 

 

 

 

 

 

or

 

 

 

 

 

 

b) Activate the device by faulting or restoring the input you wish to use for

 

 

 

 

 

 

that zone (e.g., press a button, open or close a door, etc.).

Ð 5 Ð

Page 119
Image 119
Guardian Technologies VISTA-40 An input type of RF, UR, BR, or SL if serial polling loop, Devices enabled programmed