The following is a list of choices for (ZT):

CHOICES FOR ZONE TYPES:

00 = No Response (Not Used)

01 = Entry/Exit #1

02 = Entry/exit #2

03 = Perimeter

04 = Interior Follower

05 = Trouble Day/Alarm Night

06 = 24 Hr Silent

07 = 24 Hr Audible

08 = 24 Hr Aux

09 = Fire Alarm or Trouble

10 = Interior w/Delay

23 = No alarm response

CHOICES FOR SYSTEM OPERATION:

20 = Arming-Stay (5800 RF)

21 = Arming-Away (5800 RF)

22 = Disarming (Code+Off) (5800 RF)

31 = End of Exit Time

32 = Start of Entry Time

33 = Any Burglary Alarm

34 = Code + # + 71 Key Entry

35 = Code + # + 72 Key Entry

36 = At Bell Timeout **

37 = 2 Times Bell Timeout**

38 = Chime

39 = Any Fire Alarm

40 = Bypassing

41 = AC Power Fail

42 = System Battery Low

43 = Communication failure

44 = RF low battery

45 = Polling loop failure

47 = Keypad failure

51 = RF receiver failure

52 = kissoff

54 = fire zone reset

55 = disarm + 1 minute

56 = XX minutes (enter XX in field 1*74; stop condition only)

57 = YY seconds (enter YY in field 1*75; stop

Êcondition only) 58 = Duress

60 = Select only if a non-Ademco AAV unit is being used; also select for Start and Stop if a 4204 relay module is being used.

64 = VIM Fail

65 = VIM Active

66 = VIM Inactive

**Or at Disarming, whichever occurs earlier

S T O P

The "STOP" programming determines when and under what conditions the relay will deactivate. The following items can be programmed: Restore Zone List, Zone type/System Operation, and Partition.

1)RESTORE ZONE LIST (ZL)....If a "RESTORE ZONE LIST" is used, the relay action will deactivate when all the zones in that list restore from a previous fault or alarm condition. This will occur regardless of what is programmed to start the relay, therefore, a "RESTORE ZONE LIST" would normally only be used when a "ZONE LIST" is used to start the relay.

2)ZONE TYPE/SYSTEM OPERATION (ZT)....Instead of using a "RESTORE ZONE LIST" , a specific zone response type or action can be selected to deactivate the relay. If a specific zone response type is chosen, any zone of that type that restores from a previous alarm, trouble, or fault condition will cause the relay to deactivate. If a "SYSTEM OPERATION" is chosen, that operation will cause the relay to deactivate.

Relay Programming From #93 Menu Mode, select Relay Programming Menu.

Menus

Press [*] to advance to next screen. Press # to backup to previous screen.

ENTER RELAY NO. (00=QUIT) 01

Enter the relay (output device) identification number 1 - 8 . This is a reference number only, for identification purposes. The actual module address and relay number on the module are programmed in the last two prompts.