Wireless Options (cont.)

1 * 5 7

Enable 5800

 

RF Button

 

Global Arm

1 * 5 8

Enable 5800

 

RF Button

 

Force Bypass

Partitioning Options

2 * 0 0 Number Of Partitions

2 * 1 7 Number Of User

Codes Per

Partition

2 * 1 9 Use Partition Descriptors

Enter 1 to have the system arm/disarm in accordance with the button's user's global arming settings. Enter 0 if the button is not to be used to global arm the system (however, home partition arming will still occur).

Enter 1 to allow the RF Button user to force bypass all faulted zones. When attempting to arm the system, the keypad will beep once after pressing the button, if any faulted zones are present. If this feature is enabled, the user should then press the button again within 4 seconds to force bypass those zones and arm the system. Must be disabled for UL installations.

Enter the number of partitions 1-2 to be used in the system.

Enter 01-69for each partition used in the system. Enter 01 for an unused partition. Total number of user codes in the system must be less than or equal to

70.Note that one user number is automatically assigned (installer code) to each partition, regardless of whether that partition has been enabled.

Enter 1 if partition descriptors will be programmed. If enabled, certain keypad displays will include a partition number and the partition descriptor (if programmed in #93 Menu Mode). Entering 0 causes the keypads to display a non-partitioned system type of display (no partition number will appear).

Relay Output Options

SECOND PAGE FIELDS

 

1 * 7 4

Relay

Timeout

Enter the relay timeout, 0-127in multiples of 2 minutes, desired for #93 Menu

 

XX Minutes

Mode Relay Programming output command "56" (refer to the #93 Menu Mode

 

 

 

section in this manual).

1 * 7 5

Relay

Timeout

Enter the relay timeout, 0-127seconds, desired for #93 Menu Mode Relay

YYSeconds Programming command "57" (refer to the #93 Menu Mode section in this manual).

Real-Time Clock Options

THIRD PAGE FIELDS

 

 

2 * 0 1

Daylight

Enter the months 00-12in which daylight savings time starts and ends. Enter

 

Savings Time

00, 00 if daylight savings time does not apply to the user's region. Standard

 

Start/End Month

setting for U.S. is 04,10.

2 * 0 2

Daylight

Enter the start and end weekends for daylight savings time as follows: 1=first;

 

Savings Time

2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last. Standard

 

Start/End

setting for U.S. is 01,05.

 

Weekend

 

Event Logging Options

SECOND PAGE FIELDS

 

1 * 7 0

Event

Log

Enter 1 for each of the types of events for which event logging is desired, as

 

Types

 

shown on the programming form. Otherwise enter 0.

1 * 7 1

12/24

Hour Time

Select the type of time stamping desired: 0 = standard 12 hour; 1 = 24 hour

 

Stamp Format

format.