The following table highlights the features of each receiver.

 

 

 

 

 

 

 

Feature

 

4281 series

5881 series

 

 

 

 

 

 

 

 

Wiring

 

Connects to keypad lines

Connects to keypad lines

 

 

 

 

 

 

 

 

House ID

 

Programmed via #93

Programmed via #93

 

 

 

 

 

Menu Mode.

Menu Mode (needed only

 

 

 

 

 

 

if RF keypad used).

 

 

 

 

 

 

 

 

Receiver Address

 

Set via DIP switches.

Set via DIP switches.

 

 

 

 

 

Enabled via #93 Device

Enabled via #93 Device

 

 

 

 

 

Programming.

Programming.

 

 

 

 

 

 

 

 

Cover Removal

 

Does not cause alarm or

Does not cause alarm or

 

 

 

 

 

trouble.

trouble.

 

 

 

 

 

 

 

 

Go/No Go Mode

 

Automatic upon entering

Automatic upon entering

 

 

 

 

 

test mode (code + [5]).

test mode (code + [5]).

 

 

 

 

 

 

 

 

Spatial Diversity

 

Yes. Eliminates nulls and

Yes. Eliminates nulls and

 

 

(2 antennas)

 

voids.

voids.

 

 

 

 

 

2nd receiver expands

2nd receiver expands

 

 

 

 

 

coverage area or provides

coverage area or provides

 

 

 

 

 

additional redundancy.

additional redundancy.

 

 

 

 

 

 

 

 

Transmitter ID

 

Set via DIP switches.

Serial numbers are

 

 

 

 

 

 

"enrolled" by the system

 

 

 

 

 

 

or downloaded.

 

 

 

 

 

 

 

 

4281 Series Receiver

¥

Set field 1*32 to 1.

 

 

 

 

¥

Using #93 Menu modeÐDevice Programming, select as RF device type (type 3).

 

¥

Set house ID via #93 Menu Mode.

 

 

 

¥

Set receiver's device address (01-07 only) using its DIP switches. Lower

 

 

numbered address is primary receiver (supervisory fault ID 90, 91). Higher

 

 

numbered address is secondary receiver (receiver fault ID 88, 89).

 

¥

Important: 4281 microprocessor must have part number N5334Vx, where x

 

 

is any number. The microprocessor is located just above the DIP switch on the

 

 

PC board.

 

 

 

5881 Series Receiver

¥

Set field 1*32 to Ò2Ó.

 

 

 

¥

Using #93 Menu ModeÐDevice Programming, select as RF device type (type 3).

 

¥

Set house ID via #93 Menu Mode (needed for 5827 keypad only).

 

¥

Set receiver's device address (01-07 only) using its DIP switches. Lower

 

 

numbered address is primary receiver (supervisory fault ID 90, 91). Higher

 

 

numbered address is secondary receiver (receiver fault ID 88, 89).